What Is Compressed Air? How It Is Made, What a System Includes and What It Costs to Run
HCEM Engineering TeamShare
Compressed air is ordinary atmospheric air that a compressor has squeezed into a smaller volume and holds above atmospheric pressure, so it can store energy and deliver it where it is needed. It is so widely used that Atlas Copco calls it the fourth utility, after water, electricity and gas. It is also one of the most expensive ways to deliver energy in a plant: a Compressed Air Challenge fact sheet, published with the US Department of Energy, puts the typical overall efficiency of compressed air in industrial plants at around 10%. This guide explains what happens to air when it is compressed, what a compressed air system is made of, and how much electricity it takes to make, worked out from the spec tables of HCEM oil-free piston pumps. At the average US commercial electricity rate, a 700 to 800 kPa pump of this size uses at most about 2.4 to 3.5 cents of electricity per 1,000 liters of intake air, and the same HC680 pump size built for 200 kPa needs less than half the energy per liter of the 700 kPa version, based on the maximum power in the spec tables.
The guide is written for engineers who build small compressors into equipment, such as oxygen concentrators, nitrogen and ozone generators, and dental or laboratory air units, and for anyone who wants to understand what compressed air is before choosing a compressor. Each part of the air treatment chain has its own guide: the aftercooler, the water separator, the compressed air filter and the air dryer. This page shows how they fit together.
What is compressed air?
Quincy Compressor defines compressed air as atmospheric air that has been reduced in volume and stored under pressure, and notes that many people consider it a utility in the same way as water and natural gas. Atlas Copco adds that air is a mixture of gases, mostly nitrogen (78%) and oxygen (21%), and that compressing it forces the molecules closer together. The energy used to do that is stored in the air until it is released, which is why compressed air works as a way to store and carry energy.
Two things happen when air is compressed:
- The volume shrinks. Once the air has cooled back to the temperature it entered at, its volume falls in proportion to the absolute pressure. Standard atmospheric pressure is 101.325 kPa (NIST). At 700 kPa on the gauge, the absolute pressure is about 801 kPa, so 1 liter of intake air ends up as about 0.13 liter. At 200 kPa gauge it ends up as about 0.34 liter, and at 140 kPa gauge as about 0.42 liter.
- The air gets hot. Atlas Copco calls this the heat of compression: squeezing the air makes its molecules move faster, and temperature is a measure of that motion. Hot air leaving the compressor holds the water vapor it took in, and that water condenses as the air cools. Our aftercooler guide works out how much water that is for each HCEM model.
Pressure on a compressor spec sheet is almost always gauge pressure, measured above the surrounding atmosphere. If you are not sure which one a sheet uses, see our guides to gauge and absolute pressure and to bar, kPa and psi. Flow is given as a volume per minute, in liters per minute or cubic feet per minute; our CFM guide explains CFM, SCFM and ACFM and how to convert them.
Why is compressed air used at all?
Atlas Copco gives several reasons: safety, flexibility, lighter tools and the cost of the equipment that uses it. Compressed air can be used where electrical equipment would be a shock or fire risk, for example on wet floors or in humid areas. It is easy to bring to remote sites. Tools powered by it can be made lighter, which reduces worker fatigue. And the equipment that runs on it is lower in cost, has fewer parts and tends to be rugged and long lived. Atlas Copco also notes that the cost equivalent of compressed air can be as high as 7 to 8 times that of electricity.
In the equipment our customers build, compressed air is often part of the product rather than a power source. An oxygen concentrator pushes air through a sieve bed, a nitrogen generator needs a steady feed of clean, dry air, an ozone generator needs dry feed air, and a dental unit needs air clean enough to reach a patient. In all of these the compressor is sized to a flow at a pressure, and the air quality is set by the treatment that follows it.
How is compressed air made?
Quincy divides compressors into two families:
- Positive displacement compressors trap air in a space and make the space smaller. Piston compressors, including HCEM's oil-free piston pumps, work this way: the piston draws air into the cylinder, then pushes it out through a valve at a higher pressure. See what is a piston compressor for the details.
- Dynamic compressors speed the air up to a high velocity and turn that speed into pressure.
An oil-free compressor adds no lubricant to the air in the compression chamber. It does not clean the air it takes in, though: dust, water vapor and any hydrocarbon vapor in the intake air go through the compressor and are concentrated by it. That is why oil-free machines still need filters and drains, and why the air quality class you need, for example under ISO 8573-1, decides the treatment, not the compressor alone.
What is a compressed air system made of?
Atlas Copco and Quincy both list the core parts. The table combines their lists with the treatment steps covered in our other guides, in the order the air meets them:
| Part | What it does | Our guide |
|---|---|---|
| Intake filter | Traps airborne particles such as dust and pollen before they reach the compressor (Quincy). | Compressed air filters |
| Compressor | Raises the air to the working pressure. | Piston compressors |
| Aftercooler | Cools the hot air leaving the compressor, so water condenses where it can be drained. | Aftercoolers |
| Water separator and drain | Removes the liquid water and lets it out of the system. | Water separators |
| Air receiver | Stores air to meet peaks in demand and steadies the pressure (Atlas Copco, Quincy). | Receiver sizing |
| Dryer | Lowers the moisture further, so no more water condenses downstream. | Air dryers |
| Line filters | Remove particles, oil aerosol and vapor to the quality the use needs. | Compressed air filters |
| Piping and regulators | Carry the air to the point of use and hold the pressure the use needs. | Pressure drop calculator |
A small system built into a machine may have only some of these, but the order stays the same. Quincy notes that compressed air systems can last 10 to 15 years on average, and that the two most common causes of early failure are improper installation and improper maintenance.
How much energy does it take to compress air?
Physics sets a minimum. If air could be compressed while being kept at its intake temperature (an isothermal process), the work would be the smallest possible. If it were compressed with no heat lost at all (an adiabatic process, with the ratio of specific heats of 1.4 that HyperPhysics gives for air), the work would be larger. A real compressor sits above both, because the motor, the friction of the moving parts and the heating of the air during compression all add to the input.
Here is the calculation for the HCEM HC680B-60/7, a twin-cylinder oil-free piston pump rated 60 L/min at 700 kPa with a power of at most 610 W at rated pressure (110 V/60 Hz version):
- 60 L/min is 0.001 m³/s, and the pressure ratio is 801.3 / 101.3 = 7.91.
- Minimum (isothermal) power: 101,325 Pa × 0.001 m³/s × ln(7.91) = about 210 W.
- Ideal single-stage adiabatic power: about 286 W.
- Rated input: at most 610 W. So at least about 34% of the input is the theoretical minimum, and the ideal adiabatic figure is at least about 47% of it.
These are our estimates. They assume the rated flow is measured at intake conditions at sea level, because the spec tables do not state the reference conditions for flow, and they use the maximum power the tables give, so the real shares may be higher.
The same arithmetic for the other pumps gives the table below. The cost column uses 14.27 cents per kWh, the average US commercial electricity price for September 2026 in the US Energy Information Administration's Electric Power Monthly (a preliminary figure). The average industrial price in the same table is 9.52 cents and the residential price 18.17 cents, so scale the cost to your own rate.
| Model (110 V/60 Hz) | Rated flow | Power (max) | Watts per L/min (at most) | kWh per 1,000 L (at most) | Minimum power | Minimum as share of input (at least) | Cost per 8 h at 14.27 cents (at most) |
|---|---|---|---|---|---|---|---|
| HC280B-25/7 | 25 L/min @ 700 kPa | 370 W | 14.8 | 0.25 | 87 W | 24% | $0.42 |
| HC480B-45/7 | 45 L/min @ 700 kPa | 560 W | 12.4 | 0.21 | 157 W | 28% | $0.64 |
| HC580B-60/7 | 60 L/min @ 700 kPa | 690 W | 11.5 | 0.19 | 210 W | 30% | $0.79 |
| HC680B-60/7 | 60 L/min @ 700 kPa | 610 W | 10.2 | 0.17 | 210 W | 34% | $0.70 |
| HC1100B-100/8 | 100 L/min @ 800 kPa | 1,100 W | 11.0 | 0.18 | 369 W | 34% | $1.26 |
| HC1500B-120/8 | 120 L/min @ 800 kPa | 1,500 W | 12.5 | 0.21 | 443 W | 30% | $1.71 |
| HC80B-17/1.4 | 21 L/min @ 140 kPa | 90 W | 4.3 | 0.071 | 31 W | 34% | $0.10 |
| HC210B-50/1.4 | ≥50 L/min @ 140 kPa | 230 W | 4.6 | 0.077 | ≥73 W | 32% | $0.26 |
| HC100B-38/2 | ≥38 L/min @ 200 kPa | 220 W | 5.8 | 0.096 | ≥70 W | 32% | $0.25 |
| HC280B-70/2 | ≥70 L/min @ 200 kPa | 370 W | 5.3 | 0.088 | ≥129 W | 35% | $0.42 |
| HC580B-120/2 | ≥120 L/min @ 200 kPa | 580 W | 4.8 | 0.081 | ≥221 W | 38% | $0.66 |
| HC680B-130/2 | ≥130 L/min @ 200 kPa | 600 W | 4.6 | 0.077 | ≥239 W | 40% | $0.68 |
How to read it: "Power (max)" is the upper limit the spec table gives (shown there as ≤). "Minimum power" is the isothermal figure for the rated flow and pressure, and "Minimum as share of input" is that minimum divided by the maximum power. Because the power is a maximum, every per-liter and cost figure is an upper limit and every share is a lower limit. The cost assumes the pump runs at full rated power for 8 hours. The last six rows are oxygen concentrator compressors, whose tables give the flow as a minimum (≥) for every model except the HC80B, which lists 21 L/min; for those models the minimum power is also a lower limit. We treat the rated flow as intake air; on that basis 60 L/min is about 2.1 cfm.
Per 1,000 liters of intake air, that works out to at most about 2.4 to 3.5 cents at 700 to 800 kPa and about 1.0 to 1.4 cents at 140 to 200 kPa, at the commercial rate. Over a year of one 8-hour shift on 250 days, the HC680B-60/7 uses at most about 1,220 kWh, or about $174 at 14.27 cents.
Why pressure is one of the biggest levers on energy use
Compare two pumps of the same HC680 series. At 700 kPa, the HC680B-60/7 needs about 10.2 W for each liter per minute. At 200 kPa, the HC680B-130/2 needs at most about 4.6 W, less than half. Physics accounts for most of the gap: the minimum work per liter is about 1.9 times as large at 700 kPa as at 200 kPa, because it grows with the logarithm of the pressure ratio.
The lesson for a designer is to compress only to the pressure the process needs. Atlas Copco's maintenance advice says the same: running a system at a higher pressure than required can waste energy and strain the equipment. The Compressed Air Challenge adds that a use without a pressure regulator runs at full system pressure, which raises both the air demand and the energy used. If your device needs 150 kPa, a pump rated near 200 kPa is usually the more efficient choice. The spec tables give power only at the rated pressure, so ask us for the flow and power at your operating point.
Where compressed air is wasted
Because the electricity is the main cost, waste matters more than the purchase price. Quincy puts electricity at about 76% of the lifetime cost of an air compressor (citing Energy Star), with equipment and installation at about 12% and maintenance at about 12%. Quincy also says it found that nearly half of all compressed air is wasted.
- Leaks. The Compressed Air Challenge says leaks sometimes waste 20 to 30% of a compressor's output in an industrial system, that a typical plant that has not been well maintained will likely have a leak rate equal to about 20% of its capacity, and that finding and fixing leaks can bring this below 10%. Common leak points are couplings, tubes and fittings, pressure regulators, open condensate traps and shut-off valves, and pipe joints, disconnects and thread sealants. A lower system pressure also lowers the leak rate. The fact sheet calls an ultrasonic acoustic detector the best way to find leaks; soapy water brushed onto suspect joints is reliable but slower. For sealed vacuum and pressure circuits inside a machine, see our leak rate guide.
- Uses better served by something else. The Compressed Air Challenge calls compressed air probably the most expensive form of energy in a plant and lists cheaper alternatives: blowers for cooling, mixing or moving parts; brushes, blowers or vacuum systems for cleaning; and a vacuum system instead of making vacuum by flowing high-pressure air past an orifice. If your machine needs vacuum, a vacuum pump is usually the more efficient way to make it.
- Dirty intake filters. Quincy says keeping air filters clean can lower a compressed air system's electricity use by 5 to 15%.
- Running when nothing needs air. In our experience, a small pump that runs continuously at a low load uses more energy and wears faster than one that can stop. See our duty cycle guide and size a receiver so the pump can stop.
How to compare compressors on energy
The Compressed Air Challenge's fact sheet on packaged compressor efficiency (written for industrial compressors) warns that published ratings are not always comparable. Its advice applies to small pumps too:
- Compare total electrical input per unit of flow, which includes the motor and accessories, rather than motor nameplate ratings.
- Check that both machines were rated at the same pressure and under the same reference conditions. The fact sheet notes that makers may test under different "standard" conditions.
- Ask whether figures are at full load only, and whether ranges or tolerances apply to them.
For HCEM pumps, the spec tables give the flow at the rated pressure and the power as a maximum (for most models stated at the rated pressure). They do not state the reference conditions of the flow figure. If you are comparing pumps closely, send us the operating point you need and we will confirm the flow and the input power there.
Is compressed air safe?
Atlas Copco calls compressed air relatively safe compared with other ways of storing energy, such as batteries or steam. It is still stored energy and must be treated with respect. For cleaning, the US Occupational Safety and Health Administration rule 29 CFR 1910.242(b) says: "Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment." 30 psi is about 207 kPa. Pressure vessels, relief valves and electrical safety in your equipment follow the standards that apply to your product.
Checklist: specifying compressed air for your equipment
- Write down the pressure the process needs at the point of use, plus a margin for pressure drop, and no more.
- Write down the flow at that pressure, and whether the demand is continuous or intermittent.
- Pick a pump rated for that pressure band; a low-pressure pump uses far less energy per liter.
- Decide the air quality the use needs, and plan the aftercooler, water separator, drain, filters and dryer to reach it.
- Add a receiver if demand comes in peaks, so the pump can rest.
- Estimate the energy: maximum power in kW times hours times your electricity rate.
- Seal and test every joint, and fit a regulator where a use needs less than full pressure.
Common questions
What is compressed air in simple terms?
Ordinary air pushed into a smaller space so that it is above atmospheric pressure. The energy used to compress it is stored in the air and is released when the air is let out to do work.
Is compressed air the same as oxygen?
No. Compressed air has the same make-up as the air around us, mostly nitrogen (78%) and oxygen (21%), according to Atlas Copco. Oxygen concentrators use compressed air to separate oxygen from nitrogen; the compressor itself does not change the gas mix.
Why is compressed air so expensive?
Because most of the electricity a compressor uses does not end up as useful work at the point of use. A 1998 Compressed Air Challenge fact sheet on compressed air in industrial plants puts typical overall efficiency at around 10%. That is a figure for the whole system as used, so it is lower than the pump-only shares in our table. Leaks, too much pressure and uses that a blower or vacuum pump could do more cheaply make it worse.
How much electricity does a small air compressor use?
Multiply its input power in kW by the hours it runs. For the HCEM pumps above, that is at most about 0.17 to 0.25 kWh per 1,000 liters of intake air at 700 to 800 kPa and at most about 0.07 to 0.10 kWh at 140 to 200 kPa, based on the maximum power in their spec tables.
What does "oil-free compressed air" mean?
That the compressor adds no lubricant to the air. The air can still carry dust, water and hydrocarbon vapor from the intake, so filters and dryers are still needed for clean, dry air.
Does HCEM sell complete compressed air systems?
We make oil-free piston air pumps, oxygen concentrator compressors and vacuum pumps for equipment makers. Aftercoolers, separators, filters, dryers and receivers belong to your system design; send us your flow, pressure and duty, and we will help you choose the pump and estimate its energy use.
Building compressed air into your equipment? We make oil-free piston air pumps and oxygen concentrator compressors for equipment makers and distributors. Custom voltage and logo start at 50 units, and qualified OEM customers and distributors can apply for samples (subject to review), which take 10 to 20 days. See our AC air pumps, our oxygen concentrator compressors and the OEM and ODM page, or send us your flow, working pressure, duty cycle and where the pump will be installed.
Sources
All read 2026-11-27 unless noted.
- Atlas Copco: Compressed Air: What is it and Why Do We Use it.
- Quincy Compressor: Compressed Air Systems: An Introduction and How Much Will Compressed Air Cost You?
- Compressed Air Challenge and US Department of Energy, Improving Compressed Air System Performance: Fact Sheet 2, Inappropriate Uses of Compressed Air and Fact Sheet 8, Packaged Compressor Efficiency Ratings (read 2026-11-25), and Fact Sheet 7, Compressed Air System Leaks (read 2026-11-24).
- US Occupational Safety and Health Administration: 29 CFR 1910.242, Hand and portable powered tools and equipment, general.
- US Energy Information Administration, Electric Power Monthly: Table 5.6.A, Average Price of Electricity to Ultimate Customers by End-Use Sector (September 2026, preliminary).
- NIST: CODATA value: standard atmosphere.
- HyperPhysics, Georgia State University: Isothermal Process and Adiabatic Process (the latter read 2026-11-23).
- HCEM spec tables for the models named, 110 V/60 Hz versions (store data of 2026-11-26).