Air Compressor for Ozone Generators: Oil-Free Feed Air, Dew Point, Pressure and Flow Sizing
HCEM Engineering TeamShare
An air compressor for an ozone generator has one job: to deliver a steady flow of clean, dry, cool air to the ozone cell at the pressure the system needs. The air must be oil-free, because oil fouls the cell and is a fire risk next to ozone, and dry, because water vapour cuts ozone output and forms nitric acid in the cell. Flow follows the grams of ozone per hour; pressure follows the dryer, the cell and the injection depth. For a typical 5–30 g/h air-fed generator, that means an oil-free pump of about 10–50 L/min at 1–2 bar, or a 7 bar pump feeding a heatless dryer.
This guide is for engineers who build ozone systems with a compressor inside, from water treatment skids to odour-control cabinets. It covers oil-free feed air, dew point, flow and pressure sizing, and the choice between AC and DC pumps. The worked examples use datasheet values from our own oil-free piston compressors.
Why does an ozone generator need a compressor at all?
A corona-discharge (CD) cell makes ozone by passing oxygen-bearing gas through a high-voltage discharge gap, where some oxygen (O₂) splits and recombines as ozone (O₃). The cell needs a constant, measured flow: too little and the gas overheats and the ozone breaks down; too much and the concentration falls.
Very small generators draw room air through with a fan. Once the system includes a dryer or oxygen concentrator, a flowmeter, a check valve and a diffuser under water, a fan can no longer push the air through. A compressor supplies that pressure and keeps the flow steady while filters load up: an "ozone system with compressor".
Why must the feed air be oil-free?
Oil in the feed gas causes three problems:
- It damages the cell. Oil deposits on the dielectric and electrodes, carbonises in the discharge and creates hot spots that lead to arcing and a cracked dielectric.
- It is a fire risk. Ozone is one of the strongest oxidisers in common use, and oxygen-fed systems also carry oxygen-enriched gas. Hydrocarbons collecting in a dryer, fitting or cell are fuel waiting for a spark.
- It poisons what sits upstream. Oil coats dryer desiccant and the zeolite sieve of an oxygen concentrator, so the dew point or oxygen purity drifts and never recovers.
Coalescing filters behind an oil-lubricated compressor remove droplets, but oil vapour passes through them. An oil-free piston compressor has no oil in its compression chamber, so there is none to carry over. The air still carries whatever the intake draws in, so filter the intake and keep it away from solvent fumes and exhaust. Our guide to ISO 8573-1 air purity classes explains how oil content is specified and measured.
One more point: ozone attacks many rubbers and plastics. Fit a check valve between the cell and the injection point so that water and ozone cannot flow back into the dryer and compressor when the system stops.
How does dew point affect ozone output?
Water vapour is the main enemy of a corona cell. It absorbs discharge energy that would otherwise make ozone, helps the ozone break down again, and in air-fed cells reacts with the nitrogen oxides the discharge also makes, forming nitric acid that corrodes electrodes and fittings.
Cell makers normally state dryness as an atmospheric dew point, because the gas leaves the cell and its injector near atmospheric pressure. A common design target for air-fed CD cells is −60 °C or drier; many small generators accept −40 °C. Your cell maker's figure is the one that counts. Here is the water each dew point leaves in the air:
| Atmospheric dew point | Water vapour, about | Water per m³ of air (0 °C, 1.013 bar), about | What it means for an ozone cell |
|---|---|---|---|
| +3 °C | 7,500 ppm | 6 g | Far too wet: heavy acid formation and low output |
| −20 °C | 1,000 ppm | 0.8 g | Still too wet for continuous duty |
| −40 °C | 130 ppm | 0.1 g | Accepted by many small air-fed generators |
| −60 °C | 11 ppm | 9 mg | A common target for air-fed CD cells |
| −70 °C | 2.6 ppm | 2 mg | The order of dryness a heatless desiccant dryer reaches when it is working well |
Worked example. 22 L/min of air (1.33 m³/h) at −20 °C dew point carries about 0.8 g × 1.33 ≈ 1.1 g of water an hour into the cell, about 26 g a day. At −60 °C it carries about 9 mg × 1.33 ≈ 12 mg an hour, about 0.3 g a day: about ninety times less.
Is a refrigerated dryer enough for an ozone generator?
Usually not. A refrigerated dryer cools compressed air to a pressure dew point of about +3 °C. When that air expands in the cell its dew point falls, but not far enough, and the lower the working pressure, the less it falls:
- At 7 bar gauge (8.0 bar absolute), air at a +3 °C pressure dew point carries about 0.76 kPa ÷ 801 kPa ≈ 950 ppm of water vapour. At atmospheric pressure that is a dew point of about −21 °C.
- At 2 bar gauge (3.0 bar absolute), the same +3 °C pressure dew point gives 0.76 ÷ 301 ≈ 2,500 ppm, which is a dew point of only about −10 °C at atmospheric pressure.
Both are well short of −40 °C, which is why ozone systems use desiccant drying or an oxygen concentrator, sometimes behind an aftercooler or refrigerated dryer that removes the bulk of the water. In ISO 8573-1 terms, a pressure dew point of −40 °C is water class 2 and −70 °C is class 1; note these are pressure dew points, not the atmospheric figure cell makers quote. See our guide to air dryers for oil-free compressors for dryer types and sizing.
Which feed-gas set-up should you design around?
The feed-gas route decides what the compressor has to deliver:
| Set-up | Typical dew point at the cell | What the compressor must do | Notes |
|---|---|---|---|
| Room air, no dryer | Whatever the weather gives | Low pressure, low flow | Small, intermittent units only; output follows the humidity |
| Air through a desiccant cartridge | −40 °C or drier while the cartridge is fresh | Low pressure, steady flow | Simple; cartridge changed or regenerated on a schedule |
| Air through a heatless (pressure-swing) desiccant dryer | −40 to −70 °C | Cell flow plus the dryer's purge air, at the dryer's working pressure | Continuous drying; the purge share rises as the pressure falls |
| Air into an oxygen concentrator, oxygen into the cell | Typically −60 °C or drier | The concentrator's air demand at its working pressure | Highest ozone concentration, far less nitric acid |
The heatless dryer changes the compressor size. One tower dries the air while the other is regenerated by dry air expanded to atmospheric pressure. That purge must sweep at least the same actual volume as the air being dried, so its share of the inlet flow is at least atmospheric pressure ÷ absolute working pressure:
- at 7 bar gauge: 1.013 ÷ 8.013 ≈ 13%, which is why dryer makers commonly quote 15–20% at 7 bar;
- at 2 bar gauge: 1.013 ÷ 3.013 ≈ 34%, so a third of the compressor's air never reaches the cell.
Many standard heatless dryers also need 4 bar or more at the inlet, so a 2 bar system needs a dryer built for low pressure. A low-pressure system is simpler and quieter; a 7 bar system dries more efficiently and regulates down to the cell's pressure. The sizing table shows both.
How much air does an ozone generator need?
Start from the ozone output (g/h) and the concentration your cell gives at that output (g per m³ of feed gas):
Feed-gas flow (L/min) = ozone output (g/h) × 1000 ÷ (concentration (g/m³) × 60)
As a guide, air-fed CD cells commonly run at about 10–25 g/m³ and oxygen-fed cells at about 80–150 g/m³; concentration falls as flow rises, so take the figure from your cell's curve. The table assumes an air-fed cell at 15 g/m³, then adds the heatless dryer's purge: compressor flow = cell flow ÷ 0.65 at 2 bar gauge (34% purge, plus a small allowance) and cell flow ÷ 0.80 at 7 bar gauge (20% purge, the upper end of what dryer makers quote).
| Ozone output | Air to the cell at 15 g/m³ | Compressor flow, 2 bar route | HCEM model, 2 bar route | Compressor flow, 7 bar route | HCEM model, 7 bar route |
|---|---|---|---|---|---|
| 5 g/h | 5.6 L/min | 8.6 L/min | HC100-30/2 (≥30 L/min at 200 kPa) | 6.9 L/min | HC100-9/7 (9 L/min at 700 kPa) |
| 10 g/h | 11.1 L/min | 17.1 L/min | HC100-30/2 | 13.9 L/min | HC480 (40 or 45 L/min at 700 kPa) |
| 15 g/h | 16.7 L/min | 25.6 L/min | HC100-30/2 (≥30 L/min on 220 V, ≥38 L/min on 110 V) | 20.8 L/min | HC480 |
| 30 g/h | 33.3 L/min | 51.3 L/min | HC580 medical oxygenation pump (≥120 L/min at 200 kPa) | 41.7 L/min | HC580 or HC680 (60 L/min at 700 kPa) |
| 60 g/h | 66.7 L/min | 103 L/min | HC580 medical oxygenation pump | 83.3 L/min | HC1100 (100 L/min at 800 kPa; regulate to the dryer's 7 bar) |
Read it as a first selection. Each model leaves at least 15% headroom over its row's compressor flow; keep that margin for ring wear, a loaded intake filter and warm days. The 2 bar route assumes a heatless dryer built for low inlet pressure, or a desiccant cartridge (no purge). With a cartridge, the compressor flow equals the cell flow. A pump rated at 200 kPa must not be run at 7 bar. A 7 bar pump delivers more flow at lower pressure, but take that figure from the datasheet curve, not a guess. To convert any of these flows to cfm or m³/h, use our CFM to L/min converter.
Worked example, oxygen-fed. A 30 g/h cell fed with oxygen at 100 g/m³ needs 30 × 1000 ÷ (100 × 60) = 5 L/min of oxygen. An oxygen concentrator typically needs about 8 to 12 litres of air for every litre of oxygen, depending on its sieve and cycle, so at 10:1 the compressor must supply about 50 L/min at the concentrator's working pressure. That is about the same air as the air-fed 2 bar route: oxygen feed does not save compressor air, it buys a far higher concentration that dissolves into water better. The HC580 medical oxygenation pump, built for oxygen concentrators, is rated at ≥120 L/min at 200 kPa, which covers this with room to spare. The concentrator maker's air figure overrides the 10:1 rule.
What pressure does a corona-discharge cell need?
Less than most people expect. Many small and medium cells run at roughly 0.5 to 1.5 bar gauge, and the cell's maximum is a hard limit, so a regulator before the cell is standard. The compressor must supply the sum of everything between its outlet and the end of the gas line:
| Item | Example value | Where the number comes from |
|---|---|---|
| Water depth at the diffuser, 3 m | 0.29 bar | 0.098 bar per metre of water |
| Diffuser opening pressure | 0.15 bar | Diffuser datasheet (assumed here) |
| Cell, flowmeter and check valve | 0.20 bar | Component datasheets (assumed here) |
| Dryer or concentrator loss | 0.20 bar | Dryer datasheet (assumed here) |
| Regulation margin | 0.30 bar | Enough for the regulator to control |
| Compressor working pressure | about 1.1–1.2 bar gauge | Sum of the above |
A 2 bar pump such as the HC100-30/2 covers that with margin. With a venturi injector, its suction pulls the gas through and the compressor only has to overcome the dryer and the cell. A heatless dryer run at 7 bar, or injection into a pressurised pipe, is where the 7 bar pumps come in.
Temperature matters too. Compressed air leaves the pump warm, warm air loads the desiccant harder, and ozone breaks down faster in warm gas. Cool the air with metal pipe or a small aftercooler before the dryer.
Which HCEM pumps suit ozone generators?
Ozone generators are one of the uses on our solutions page. The models below cover the 2 bar and 7–8 bar routes above: the HC580 medical oxygenation pump comes from our oxygen-concentrator compressor range, the others from our AC oil-free air compressor pumps. Datasheet values:
| Model | Supply | Rated flow | In cfm | Power | Noise | Weight |
|---|---|---|---|---|---|---|
| HC100-30/2 | 220 V/50 Hz or 110 V/60 Hz | ≥30 or ≥38 L/min at 200 kPa | 1.06 or 1.34 | ≤180 W or ≤220 W | ≤52 or ≤55 dB(A) | 3.4 kg |
| HC580 medical oxygenation pump | 220 V/50 Hz or 110 V/60 Hz | ≥120 L/min at 200 kPa | 4.24 | ≤580 W | ≤62 dB(A) | 10.8 kg |
| HC480 | 220 V/50 Hz or 110 V/60 Hz | 40 or 45 L/min at 700 kPa | 1.41 or 1.59 | ≤480 W or ≤560 W | ≤65 or ≤66 dB(A) | 9.8 kg |
| HC580 | 220 V/50 Hz or 110 V/60 Hz | 60 L/min at 700 kPa | 2.12 | ≤690 W | ≤65 dB(A) | 10.1 kg |
| HC680 | 220 V/50 Hz or 110 V/60 Hz | 60 L/min at 700 kPa | 2.12 | ≤610 W | ≤60 or ≤61 dB(A) | 9.9 kg |
| HC1100 | 220 V/50 Hz or 110 V/60 Hz | 100 L/min at 800 kPa | 3.53 | ≤1100 W | ≤70 dB(A) | 17.2 kg |
Where two values are given, the first is the 220 V/50 Hz version and the second the 110 V/60 Hz version, which runs at 1700 rpm instead of 1400 rpm. For UK and European mains, specify the 220 V/50 Hz version and check its voltage tolerance on the datasheet. The HC580 and HC680 deliver the same 60 L/min at 700 kPa; the HC680 draws less power and is a few decibels quieter. Every model above lists an operating ambient of −5 to 40 °C and thermal protection at 145 ± 5 °C. For other operating points, see the datasheet on each product page.
AC or DC piston pump: which suits continuous duty?
The generator's power supply usually decides. A mains-powered skid takes an AC pump; a DC pump suits units that run from a vehicle, battery or solar system, such as mobile odour treatment. The HC580 comes in both versions with the same rated flow and the same dimensions, so the choice does not change the pneumatic design:
| Datasheet item | HC580 (AC) | HC580D (DC) |
|---|---|---|
| Supply | 220 V/50 Hz or 110 V/60 Hz | 12, 24 or 48 V DC |
| Rated flow | 60 L/min at 700 kPa | 60 L/min at 700 kPa |
| Power at rated pressure | ≤690 W | ≤690 W |
| Current at rated pressure | n/a | 57.5 A (12 V), 28.7 A (24 V), 14.3 A (48 V) |
| Dimensions | 276 × 133 × 202 mm | 276 × 133 × 202 mm |
| Noise | ≤65 dB(A) | ≤60 dB(A) |
| Net weight | 10.1 kg | 7.3 kg |
Worked example, DC. 690 W ÷ 24 V = 28.75 A, which matches the 28.7 A on the datasheet. Over an 8-hour shift the pump alone draws 28.7 A × 8 h ≈ 230 Ah from a 24 V bank, before the cell's power supply and the battery's usable depth of discharge. On 12 V the current doubles to 57.5 A, which needs heavy cable and fusing, so 24 V or 48 V is the easier design. Our guide to AC vs DC oil-free air pumps covers inrush current, supply ripple and other integration points.
Ozone generators often run around the clock. Several of our listings carry a "24h continuous duty" label; for a continuous system, ask for the duty rating at your working pressure, ambient temperature and enclosure cooling, in writing. A pump running at 2 bar has far more thermal margin than one held at 7 bar. Our duty cycle guide shows how to calculate the load, and how to size an oil-free air pump by CFM, PSI and duty cycle walks through the full selection. For flow units, see what CFM, SCFM and ACFM mean.
Common questions
Can I use an oil-lubricated workshop compressor for an ozone generator?
It is a poor choice. Even with coalescing filters, oil vapour reaches the dryer and cell, fouls the dielectric and is a fire risk with ozone. Workshop compressors are also built for intermittent use.
Do I need an oxygen concentrator, or is dry air enough?
Dry air is enough for many generators at moderate outputs. A concentrator raises the ozone concentration several times over and greatly reduces nitric acid formation, but it does not reduce the compressor's air demand.
How dry does the feed air need to be?
A common target for air-fed corona cells is an atmospheric dew point of −60 °C or drier; many small units accept −40 °C. Design to your cell maker's figure.
Can the compressor go inside the generator cabinet?
Yes, if the cabinet keeps the pump's intake air within its rated ambient range (−5 to 40 °C for the models above), the intake is filtered and away from any ozone leak, and a check valve stops backflow.
We build oil-free piston compressors for equipment makers, including OEM versions through our OEM and ODM service. If you are designing an ozone generator, send us its ozone output, feed-gas route (dried air or oxygen), working pressure, supply voltage and duty cycle, and our engineers will recommend a model.