HC580 Series — AC Oil-Free Air Compressor

Why Choose the HC580 Oilless AC Air Pump

Picture a dental clinic expanding to multiple treatment chairs, where a single pneumatic source must feed every workstation with clean, dependable air — and where even a trace of oil vapor can compromise patient safety and sensitive valves. In environments demanding both volume and absolute purity, relying on lubricated pneumatics introduces unacceptable risk. The HC580 oilless air pump guarantees a completely oil-free air supply while delivering a steady 60L/min at 700Kpa, eliminating the threat of contamination and the cost of lubrication maintenance. With a twin-cylinder, pressure-parallel-flow head, the HC580 gives OEM buyers and technical managers a dependable pneumatic core they can design around for years of service.

Key Features

  • 100% Oil-Free Operation — eliminates oil-mist contamination entirely, making it safe for dental, medical, laboratory and food-processing integration where air purity is non-negotiable.
  • High-Output Twin-Cylinder Design — heads in pressure-parallel-flow configuration deliver a consistent 60L/min at 700Kpa, with free-air delivery of up to 125L/min for demanding peak loads.
  • Quiet Performance — operates at ≤65dB(A) on both the 220V and 110V models, quiet enough for indoor clinics, laboratories and light-industrial environments.
  • Energy-Efficient Motor — consumes only ≤690W at rated pressure on both voltage models, minimizing electrical overhead for continuously operating equipment.
  • Thermal Safety — integrated thermal protection activates at 145±5°C to prevent motor overheating during intensive operation.
  • Global Voltage Flexibility — offered as HC580A-60/7 (220V/50Hz/1) and HC580B-60/7 (110V/60Hz/1), so OEMs can standardize one pneumatic platform across regional markets.
  • Wide Operating Range — functions reliably in ambient air temperatures from -5°C to 40°C.

Applications & Industries

Medical & dental focus — For the medical and dental sectors, air purity is not a preference — it is a safety requirement. The HC580 serves as the pneumatic core for multi-chair dental clinics, medical air systems and pneumatic medical tools, sustaining up to 60L/min at a steady 700Kpa so multiple workstations receive the exact pressure they need without any risk of oil mist reaching patients or internal sensors. Its ≤65dB(A) noise output keeps treatment rooms and laboratories within comfortable acoustic levels.

Industrial & food processing — In industrial automation and food and beverage processing, the HC580 provides a dependable pneumatic source for actuators, vacuum and sealing stations and automated filling lines. Food and beverage facilities must keep compressed air free of oil contamination during flushing, packaging and sealing processes — an oilless design removes that hazard at the source. The twin-cylinder parallel-flow layout sustains the higher air demand of multi-station lines, while the F-class motor and thermal protection support continuous operating cycles without lubrication downtime.

OEM integration & laboratory — Equipment manufacturers also rely on the HC580 for centralized laboratory gas supply, aeration systems and analytical instrumentation. With a compact 276×133×202mm body, an installation footprint of only 223×89mm and a net weight of 10.1kg, OEM designers can integrate the pump directly into equipment housings without extensive structural modification. Dual voltage options allow instrument manufacturers to standardize their internal pneumatic design while shipping to different global regions.

Certifications & Compliance

Procurement engineers and OEM buyers require strict quality assurance and regulatory compliance to mitigate supply-chain risk. The HC580 is manufactured in an ISO 9001-certified facility, ensuring that every unit rolling off the production line adheres to strict quality management principles — consistent manufacturing tolerances, predictable performance across large-batch orders and a commitment to continuous product improvement for industrial buyers.

Furthermore, the HC580 series supports CE and RoHS compliance. The CE mark indicates conformity with European health, safety and environmental protection standards, supporting market access for OEMs exporting equipment to the European Economic Area. RoHS compliance confirms the pump is manufactured without restricted hazardous substances such as lead, mercury or cadmium — critical for manufacturers of medical devices and food-processing machinery that must meet environmental directives and ensure end-of-life recyclability of their products.

Frequently Asked Questions

What are the electrical requirements and thermal limits of the HC580?

The HC580 is available in two configurations to suit regional power grids: the HC580A-60/7 operates on 220V/50Hz/1, drawing ≤690W and running at 1400rpm, while the HC580B-60/7 requires 110V/60Hz/1, drawing ≤690W and running at 1700rpm. Both models deliver 60L/min at 700Kpa, feature Class F motor insulation and include built-in thermal protection that triggers automatically at 145±5°C. Capacitor values are 20μF for the 220V model and 60μF for the 110V model. The pump operates safely in ambient air temperatures between -5°C and 40°C.

Is the HC580 suitable for indoor or patient-care environments requiring quiet operation?

Yes. Both the 220V and 110V models operate at ≤65dB(A), and the 100% oil-free output prevents both acoustic disruption and chemical contamination in clinics, laboratories and clean indoor facilities.

How does the HC580 mount inside OEM equipment enclosures?

The HC580 is designed for straightforward integration into OEM machinery. Overall dimensions are 276×133×202mm, with a 223×89mm mounting footprint (4×M8 holes) and a net weight of 10.1kg — allowing the twin-cylinder unit to be installed into equipment housings with minimal structural modification.

Technical Specifications

Model 220V/50Hz 110V/60Hz
Model Number HC580A-60/7 HC580B-60/7
Head Configuration Pressure parallel flow Pressure parallel flow
Voltage 220V/50Hz/1 110V/60Hz/1
Noise ≤65dB(A) ≤65dB(A)
Power at Rated Pressure ≤690W ≤690W
Air Flow Rate 60L/min@700kPa 60L/min@700kPa
Speed at Rated Pressure 1400rpm 1700rpm
Dimensions 276×133×202mm 276×133×202mm
Installation Size 223×89mm 223×89mm
Net Weight 10.1kg 10.1kg
Operating Ambient Air Temperature -5 to 40°C -5 to 40°C
Thermal Protection 145±5°C 145±5°C
Motor Insulation Class F F
Capacitor Value 20μF 60μF

Download the complete technical datasheet for specifications and performance curves.

Get a Quote

Request a Quote for This Product

Tell us your quantity and application. We will respond within 24 hours with pricing and availability.

  • Response within 24 hours
  • Free samples for qualified buyers
  • OEM / ODM customization available

Translation missing: en.By submitting you agree to our Translation missing: en.Privacy Policy.