Vacuum Bagging: How It Works, What Vacuum Level You Need and How to Choose the Pump
HCEM Engineering TeamShare
Vacuum bagging clamps a laminate with atmospheric pressure. The part is sealed in an airtight envelope (a mold on one side, a bag on the other) and a vacuum pump draws the air out, so the atmosphere outside presses every ply evenly against the mold until the resin cures. Most wet lay-ups run at 12 to 25 inHg, which is 6 to 12.5 psi of clamping pressure.
This guide covers the vacuum level each job needs, how much pump flow it takes and why leaks matter more than bag size, which pump types work, and how to set up and leak-test the system. The worked examples are written out so you can redo them for your own part.
How does vacuum bagging work?
Once the bag is sealed, the pressure inside and outside the envelope is the same: about 29.92 inHg, or 14.7 psi, at sea level. As the pump removes air, the pressure inside falls while the atmosphere outside stays the same. The difference is the clamping pressure. WEST SYSTEM's Vacuum Bagging Techniques manual (read 2026-11-07) describes it this way. It notes that the theoretical maximum is one atmosphere and that a realistic difference is 12 to 25 inHg (6 to 12.5 psi).
Compared with clamps or staples, which press only where they touch, the bag presses evenly over the whole surface. The benefits it lists include thinner, more even glue lines with fewer voids; core materials that clamps would crush or that cannot hold staples; light molds, because the atmosphere also pushes evenly on the back of the mold; and control of resin content. A wet lay-up without a bag is limited to about 50% fiber and 50% resin, while vacuum bagging can reach about 65% fiber and 35% resin.
The same envelope is used for wet lay-ups, prepregs and resin infusion. The Composites Knowledge Network (CKN) Knowledge in Practice Centre (read 2026-11-07) describes the bag's job as removing trapped air and excess resin so parts come out more consistent.
How much vacuum does vacuum bagging need?
It depends on the job, and full vacuum is not always better:
- Flat panels with a few layers of glass, flat veneers or a core. The WEST SYSTEM manual says 5 or 6 inHg (2.5 to 3 psi) is enough for a good bond.
- Curved or compound molds, and stacks of stiff veneers or core. At least 20 to 28 inHg (same manual), so the plies are forced into the mold shape.
- Typical wet lay-up. 12 to 25 inHg, the manual's realistic range.
- Prepreg and infusion bags. CKN's step-by-step bagging page gives 25 to 30 inHg as the typical target, and its infusion page notes that infusion usually runs at full vacuum (29.92 inHg), although less is acceptable for some processes.
More vacuum is not free. The manual warns that high vacuum compacts the laminate more, but it can also draw too much resin into the breather. That is most likely with a low-viscosity resin that has a long open time. Perforated film limits how much resin bleeds out. The bag also sets a limit: plain 6-mil polyethylene is suitable only below 5 psi (10 inHg) at room temperature. Above that, use purpose-made bagging film.
Most gauges read inches of mercury below atmosphere, from 0 to 30. To get psi, the manual says to divide the reading by two. The table uses the exact NIST factors (1 inHg = 3.386 kPa, 1 psi = 6.895 kPa, read 2026-11-07) and a standard atmosphere of 101.325 kPa:
| Gauge (inHg) | Gauge (kPa) | Clamping pressure (psi) | Force per ft² (lbf) | Absolute pressure in the bag (mbar) | Where it comes up |
|---|---|---|---|---|---|
| 6 | −20.3 | 2.95 | 424 | 810 | Flat panels, flat veneers (WEST SYSTEM) |
| 12 | −40.6 | 5.89 | 849 | 607 | Low end of the realistic wet lay-up range |
| 20 | −67.7 | 9.82 | 1,415 | 336 | Low end for curved molds and stiff veneers |
| 25 | −84.7 | 12.28 | 1,768 | 167 | High end of the wet lay-up range; low end of CKN's 25 to 30 |
| 27.2 | −92 | 13.34 | 1,921 | 93 | Maximum vacuum rating of HCEM's standard piston pumps |
| 28.9 | −98 | 14.21 | 2,047 | 33 | Maximum vacuum rating of HCEM's high-vacuum versions |
Worked example: clamping force. A 2 × 4 ft panel (8 ft²) at 12 inHg receives 5.89 psi × 144 in²/ft² × 8 ft² ≈ 6,790 lbf, spread evenly over the panel. The manual's own example is a 4 × 8 ft panel at 20 inHg, which receives over 46,000 pounds, using its round figure of 10 psi. A shop full of clamps could not spread that much force so evenly.
These gauge readings assume sea level. At elevation the atmosphere is thinner, so the same gauge reading leaves less clamping pressure, and the deepest gauge reading a pump can reach is lower too. See our guide to vacuum pump altitude and ambient conditions. For the different pressure scales, see gauge vs absolute pressure.
How many CFM does a vacuum bagging pump need?
The WEST SYSTEM manual's rules of thumb, with the flow in liters per minute (1 CFM = 28.3 L/min, NIST):
- A panel of a few square feet: 1 to 2 CFM (28 to 57 L/min) holds the pressure, provided the envelope is airtight.
- Flow should grow in proportion to the panel area. A large panel or a hull may need 10 CFM or more (283 L/min or more).
- Choose the pump on its maximum vacuum and its CFM, not on its horsepower. The best pump moves the most air at the vacuum you need, for a reasonable power draw.
Why does flow matter so much if a perfectly sealed bag could be pumped down by any pump in the end? Because no real bag is perfectly sealed. The manual says that a bigger CFM rating lets the pump get closer to its maximum vacuum and hold it against the bag's combined leaks, and reach clamping pressure sooner while the resin is still workable. Pump-down is rarely the limit; leakage is.
Worked example 1: pump-down. Pump-down time is t = (V ÷ S) × ln(p0 ÷ p1), as in our evacuation time guide. Assume a bag with breather, hose and trap holding 10 L of air (an assumption; measure or estimate your own). Pumping it to 25 inHg (16.7 kPa absolute) gives ln(101.3 ÷ 16.7) = 1.81. At 120 L/min that is (10 ÷ 120) × 1.81 = 0.15 min, about 9 seconds. At 45 L/min it is about 24 seconds. Real times are longer because a pump moves less air as the vacuum deepens. Even so, pump-down takes seconds, not minutes.
Worked example 2: leaks. Every liter of room air that leaks in expands as it enters the bag, so the pump has to move more than a liter at bag pressure. How much more is the ratio of atmospheric to absolute pressure:
| Working vacuum | Absolute pressure | Each 1 L/min of leak becomes | A 2 L/min leak needs |
|---|---|---|---|
| 6 inHg | 81.0 kPa | 1.25 L/min | 2.5 L/min |
| 12 inHg | 60.7 kPa | 1.67 L/min | 3.3 L/min |
| 20 inHg | 33.6 kPa | 3.02 L/min | 6.0 L/min |
| 25 inHg | 16.7 kPa | 6.08 L/min | 12.2 L/min |
| 27.2 inHg | 9.2 kPa | 11.0 L/min | 22.0 L/min |
Two lessons follow. First, a bag run at 25 inHg needs about 3.6 times the pump flow of the same bag at 12 inHg to cope with the same leak, so run at the vacuum the job needs and no more. Second, the same pump has less flow to spare near its limit, because, as the WEST SYSTEM manual's pump curve shows, free-air flow falls as the vacuum rises. A pump rated to −92 kPa (27.2 inHg) has little reserve when held at 27 inHg. Compare pumps at your working vacuum, as ultimate pressure vs working vacuum explains, and use our CFM to L/min converter for mixed units.
Which type of vacuum pump is best for vacuum bagging?
| Type | Strengths for vacuum bagging | Trade-offs |
|---|---|---|
| Oil-less piston | Reaches higher vacuum than rotary vane pumps; no oil to change or contaminate | More noise and vibration than a rotary vane pump |
| Rotary vane (oil-less or oil-lubricated) | Moves more air at a given vacuum rating, so it tolerates more leakage; compact, smooth, lower power, lower cost | Lower maximum vacuum than piston pumps, though enough for most bagging |
| Oil-lubricated pumps in general | Higher vacuum, more efficient, longer life | Oil to monitor and change |
| Diaphragm | Small and oil-free; the manual's example moves 1.2 CFM and reaches 24.0 inHg, practical for small projects | Small flow limits part size |
| Venturi (air-operated) generator | Cheap and portable if you already have a compressor; high vacuum | Moves little air, which limits part size; needs a compressor that can feed it for the whole cure |
| Vacuum cleaner (turbine) motor | High airflow | Vacuum too low for most vacuum bagging |
The table summarizes the pump-type section (2.1.5) of the WEST SYSTEM manual. It notes that oil-less pumps are cleaner, need less monitoring and maintenance, and easily reach the vacuum range bagging needs. Our diaphragm vs piston pump article compares those two designs in more detail.
Whatever the type, the manual adds one requirement that is easy to miss. The pump must hold vacuum continuously until the resin has cured, which can take 8 to 12 hours depending on the hardener and the temperature. Check that the pump is rated to run that long at your working vacuum, and keep it ventilated.
What equipment does a vacuum bagging setup need?
| Part | What it does | What to check |
|---|---|---|
| Release fabric (peel ply) or release film | Separates the laminate from the bagging layers | Peel ply leaves a textured surface ready for bonding |
| Perforated film (optional) | Limits how much resin bleeds out | Hole size and pattern suit the vacuum and the resin |
| Breather | Lets air from the whole part reach the port | Extra layer under the port; padding over sharp corners |
| Bag film and sealant tape (mastic) | Form the airtight envelope | Film rated for your vacuum and temperature; pleats at complex shapes |
| Port, hose and fittings | Connect the bag to the pump | Hose that will not collapse under vacuum (or under heat, if post-cured) |
| Resin trap (catch pot) | Catches resin before it reaches valves or the pump | As close to the bag as possible |
| Control valve and throttle (bleed) valve | The control valve sets how fast air is removed; the throttle valve is an adjustable leak that sets the bag pressure | Both close to the bag |
| Vacuum gauge | Shows the clamping pressure through the cure | Mounted on the bag, away from the port |
The roles are from WEST SYSTEM's section 2.2 and CKN's equipment list. The throttle valve is how you hold a flat veneer panel at 6 inHg with a pump that could pull 27.
How do you vacuum bag a part, step by step?
- Prepare the mold: apply release agent, or lay non-porous release film on the mold.
- Lay up the plies, pushing each one into inside corners. The manual warns that plies or bag cut too short "bridge" across corners and leave voids.
- Run sealant tape around the mold perimeter. Leave its backing paper on for now.
- Add the bagging stack: peel ply (extending at least 2 cm past the laminate, per CKN), release or perforated film, then the breather, stopping about 1 cm short of the tape.
- Place the port on an extra square of breather, outside the trim line where possible. Large parts need several ports.
- Lay the bag with enough slack and pleats that it can follow the shape without stretching, then press it onto the tape all round.
- Draw a partial vacuum first, smooth out wrinkles, then go to the working level (CKN).
- Hunt for leaks at folds, pleats, tape laps and the port, as described below.
- Keep the pump running and watch the gauge until the resin has fully cured.
How do you find and fix leaks?
- Listen. Large leaks whistle. Both sources point to the same places: bag folds and pleats, sealant laps and the perimeter, and the port connection. Press the bag into the sealant, or patch the leak with more sealant or tape.
- Watch the time. CKN says that if the target vacuum is not reached within a few minutes, either the pump lacks flow or the bag leaks. Worked example 1 shows why: a sealed bag should pump down in well under a minute.
- Do a drop test. Isolate the pump and watch the gauge. CKN's rule of thumb is a drop of no more than 2 inHg in 5 minutes, depending on part size. For a 10 L bag, that limit equals only about 0.13 L/min of leakage as free air, which hardly loads any pump.
- Be strictest for infusion. The WEST SYSTEM manual says leaks cannot be tolerated in infusion, and CKN explains why: a leak draws air into the laminate as resin flows and cures, leaving porosity. A catch pot between the bag and the pump keeps resin out of the pump. If your resin needs degassing first, see our vacuum degassing guide.
To measure the leak rate of an isolated volume and turn it into a pass or fail limit, see our vacuum leak rate guide. If the pump itself no longer reaches its rating, see how to test a vacuum pump.
What about veneer presses?
A vacuum veneer press is vacuum bagging with a reusable bag or a platen. The same numbers apply: about 5 to 6 inHg for flat veneer, and at least 20 to 28 inHg to pull stiff veneers or several layers over a curved form (WEST SYSTEM). Solid sheets such as veneer or foam core can seal around their edges and trap air and glue underneath. The manual suggests perforating them, or relying on a convex form where the center touches first. For long glue-ups, a reservoir and a vacuum switch can let the pump run only when the vacuum drops below a set level, instead of running for the whole cure. If you are designing a press, our vacuum reservoir sizing guide shows how to size the buffer volume. Related forming work is covered in the vacuum thermoforming guide.
Where does an oil-free piston pump fit, and which HCEM models?
An oil-free piston pump suits small and medium bagging, veneer presses and equipment makers building bagging or press units. There is no oil to change or to mist into a clean workshop, and the standard versions are rated to −90 or −92 kPa (26.6 to 27.2 inHg), above the 20 to 28 inHg that curved work needs. The limits are honest ones: the WEST SYSTEM manual notes that piston pumps are noisier and vibrate more than rotary vane pumps, a dry piston pump is built to move air and needs a resin trap in front of it, and none of our product pages lists composite vacuum bagging. We have not tested these pumps on bagging setups.
Parameter tables of five pumps from our oil-free vacuum pump range, quoted as listed on each product page (store data of 2026-10-31). The "Max. Open Air Flow" row gives a flow with −92 kPa (−90 kPa for the HC100A), and the "Max. Vacuum" row gives a flow with −98 kPa:
| Model | Supply | Max. Open Air Flow row | Max. Vacuum row | Power | Noise | Weight |
|---|---|---|---|---|---|---|
| HC100A / HC100B | 220 V 50 Hz / 110 V 60 Hz | 45 / 50 L/min (1.59 / 1.77 cfm); −90 kPa | 22.5 / 25 L/min; −98 kPa | ≤110 / ≤150 W | ≤50 / ≤51 dB(A) | 3.4 kg |
| HC280C / D / E | 12 / 24 / 48 V DC | 90 L/min (3.18 cfm); −92 kPa | 45 L/min; −98 kPa | ≤180 W | ≤58 dB(A) | 4.9 kg |
| HC580A / HC580B | 220 V 50 Hz / 110 V 60 Hz | 120 L/min (4.24 cfm); −92 kPa | 60 L/min; −98 kPa | ≤340 W | ≤60 / ≤61 dB(A) | 10.1 kg |
| HC680A / HC680B | 220 V 50 Hz / 110 V 60 Hz | 165 / 170 L/min (5.83 / 6.01 cfm); −92 kPa | 82.5 / 85 L/min; −98 kPa | ≤340 W | ≤60 / ≤61 dB(A) | 9.9 kg |
| HC1500A / HC1500B | 220 V 50 Hz / 110 V 60 Hz | 210 / 250 L/min (7.42 / 8.83 cfm); −92 kPa | 110 / 130 L/min; −98 kPa | ≤700 / ≤750 W | ≤69 / ≤71 dB(A) | 17.5 kg |
How these compare with the WEST SYSTEM rules of thumb, on paper only: the HC100A's 1.59 cfm and the HC280D's 3.18 cfm sit in or above the 1 to 2 CFM the manual gives for panels of a few square feet. The HC580A, HC680A and HC1500A give more room for larger panels and leakier bags. None of them reaches the 10 CFM or more the manual gives for hull-sized jobs; that work needs a larger pump or several pumps. These open-flow figures are not the flow at your working vacuum, which the tables do not give, so ask us before you design a pump into a press or bagging unit.
For the long cure, the AC tables list an ambient range of −5 to 40 °C and a thermal switch at 145 ± 5 °C. Tell us your working vacuum, cure time and enclosure, and we will confirm whether a model can run that long continuously or should be cycled with a reservoir and vacuum switch.
For equipment makers we offer custom voltages and logos from 50 units; qualified OEM customers and distributors can apply for samples (subject to review); samples take 10 to 20 days. See the OEM and ODM page.
Common questions
Can I use an HVAC or refrigeration vacuum pump for vacuum bagging?
The WEST SYSTEM manual says used pumps of many kinds can work, and a dry run following its procedure will show a pump's limits. Two things to check: the pump must run continuously for the whole cure (8 to 12 hours), and a trap must keep resin out of it. An oil-sealed pump also needs its oil looked after.
Is more vacuum always better?
No. More vacuum gives more compaction, but it can starve the laminate of resin, exceed what plain polyethylene can take (5 psi, about 10 inHg), and need far more pump flow to hold against the same leak (worked example 2). Use the level the job needs and set it with the throttle valve.
What vacuum do I need for carbon fiber?
The fiber does not set the number; the process and the shape do. A wet lay-up typically runs at 12 to 25 inHg, curved molds at 20 inHg or more, and prepreg or infusion bags at 25 to 30 inHg (WEST SYSTEM; CKN).
Choosing a pump for a bagging table, veneer press or bagging unit you build? Send us the part size, process (wet lay-up, veneer, infusion), working vacuum, cure time and supply voltage. Our engineers will suggest a model, tell you what flow data we have at your working vacuum, and tell you plainly if a piston pump is not the right fit.
Sources
All read 2026-11-07.
- WEST SYSTEM (Gougeon Brothers): Vacuum Bagging Techniques (002-150), 8th edition, PDF.
- Composites Knowledge Network, Knowledge in Practice Centre: Vacuum Bagging (P168); Vacuum Bagging for Vacuum Infusion (P173).
- NIST: Guide to the SI, Appendix B.9.