Milking Machine Vacuum Pump: Vacuum Level, CFM and How to Size It
HCEM Engineering TeamShare
A milking machine vacuum pump keeps a steady vacuum in the milking system, typically 40 to 50 kPa (about 12 to 15 inHg) for cows and a little lower for goats. It has to remove air as fast as the pulsator, the claw air vent and any leaks let it in. So the number that sizes the pump is its air flow at that working vacuum, not its open-inlet flow and not its horsepower. A commercial milking unit uses roughly 1.5 cfm (42 L/min) of free air in steady operation, and pumps are usually sized well above that.
This guide covers the vacuum level for cows and goats, how much pump capacity a bucket milker or a small pipeline needs, the rating trap that makes pump listings hard to compare (free air, expanded air, ASME and NZ ratings), the checks that keep the vacuum stable, and where an oil-free piston pump fits. The worked examples are written out so you can redo them for your own system. Settings for your animals belong to your milking equipment supplier and your herd veterinarian; this article is about the vacuum supply.
What does the vacuum pump do in a milking machine?
The FAO training manual Milking, milk production hygiene and udder health (chapter 2, read 2026-11-08) describes the same basic layout for bucket, pipeline and recorder machines: a pump that removes air from the vacuum pipeline, a vacuum regulator, and a container that collects the milk. The pump removes air at a constant rate. Air comes back in at several points:
- The pulsator, which admits air about once a second so the liner collapses on the teat. University of Florida Extension's DS64 (D. R. Bray, first published 1993 and reviewed 2003; archival copy, read 2026-11-08) puts a pulsator's use at about 1 cfm.
- The claw air vent, a small hole that helps milk move away from the claw. FAO gives 4 to 10 L/min as the range in milking machine standards.
- Leaks at joints, gaskets and the trap or tank drain.
- Unit attachment, liner slips and fall-offs, which let in large, sudden amounts of air.
- The regulator, which admits whatever the pump removes beyond what milking uses, so the vacuum stays at the set level.
DS64 states the rule simply: if air enters faster than the pump can remove it, the vacuum drops. If the pump has more capacity than the milking uses, which should always be the case, the excess comes in through the regulator. Without that air admission the pump would pull toward nearly 30 inHg, far more than milking wants. This is why the pump and the regulator are sized together: DS64 adds that the regulator's capacity should be more than the pump's.
What vacuum level does a milking machine need?
Milking machine standards use kilopascals of vacuum, with 0 kPa at atmospheric pressure and 100 kPa at absolute vacuum (FAO). Many US gauges read inches of mercury. One inHg is 3.386 kPa (FAO and NIST, both read 2026-11-08).
| Setting | kPa vacuum | inHg | Source |
|---|---|---|---|
| Normal range for cows | 40 to 50 | 11.8 to 14.8 | FAO |
| Most common levels for cows | 44 and 50 | 13.0 and 14.8 | FAO |
| Old rule of thumb, low lines | about 42 | 12.5 | UF DS64 |
| Old rule of thumb, high lines | about 47 to 51 | 14 to 15 | UF DS64 |
| Below this, units fall off at peak flow | about 37 | 11 | UF DS64 |
| Above this, teat-end damage reported | about 51 | 15 | UF DS64 |
| Goats, recommended system vacuum | 36 to 48 | 10.6 to 14.2 | Romero et al. 2021 |
Why not more vacuum? FAO explains that a higher vacuum milks faster but leaves more milk to strip, so in practice a compromise of about half an atmosphere is used. DS64 reports research showing teat-end damage above 15 inHg, and advises raising the vacuum to stop liner slip only as far as 15 inHg. For goats, a 2021 study of Murciano-Granadina goats in mid-line and low-line parlors (Romero and co-authors, Animals 12(1):40, read 2026-11-08) summarizes the recommended settings as 36 to 48 kPa system vacuum, 70 to 120 pulsation cycles per minute and a 60% pulsator ratio. In its own trial, 40 kPa gave better milk fractioning than 36 kPa in the mid-line parlor; in the low-line parlor, 36 kPa gave similar milk fractioning and better teat-end and milk cortisol values, although 40 kPa improved milking efficiency at both line heights. Breed and line height matter, which is why your equipment supplier sets the final number.
Line height matters too. FAO notes that lifting a column of milk 1 m costs about 10 kPa of vacuum, much less when air is mixed in. A bucket milker has no milk lift, which in our reading is one reason bucket and low-line systems are set at the lower end of the range.
Pulsation is set separately from the pump. FAO gives 50 to 60 cycles per minute and a ratio from 50:50 to 70:30 for cows; DS64 says 44 to 60 pulsations per minute, with 60:40 the most common ratio in new installations. FAO adds that a faster pulsation rate greatly increases the air admitted, and so the pump capacity needed.
How many CFM does a milking vacuum pump need?
Start with what the milking itself uses, then add what keeps the vacuum stable:
- Steady use per unit. DS64 says the milking uses less than 2 cfm per unit. A 1995 National Mastitis Council paper on sizing vacuum pumps for cleaning milking systems, from the University of Wisconsin-Madison Milking Research and Instruction Laboratory (Reinemann and Mein, read 2026-11-08), puts the steady air for pulsation and claw air vents at about 1.5 scfm (42 L/min) for most commercial milking units, and suggests 2 scfm (56 L/min) per unit to allow for system leaks.
- Leaks. DS64 says leakage should not exceed 10% of the pump's capacity, and that most Florida dairies had large enough pumps but too many leaks.
- The regulator. FAO says a good regulator should hold the working vacuum within ±2 kPa and leak no more than 35 L/min when nominally closed.
- Reserve for attaching units and fall-offs. FAO notes that vacuum recovers slowly after a liner slip or fall-off if pump capacity is inadequate.
For whole installations, FAO gives a pump capacity at 50 kPa of about 70 L/min of free air per unit for installations with 20 units, rising to 85 L/min per unit for small plants with 5 units, varying with the maker's design. For whole systems, the Wisconsin paper cites 35 scfm plus 3 scfm per milking unit as the capacity suggested for milking (from Mein and co-authors, 1995), and DS64's rule is 30 cfm to run the system, 10% for leaks and 3 cfm per unit; DS64 explains the 30 cfm as covering head loss and the resistance of pipes and fittings. In our reading, that fixed base is written with pipeline and parlor systems in mind and overstates what one or two bucket units need. For a small machine, FAO's per-unit figure is the better guide, and because it rises as plants get smaller (70 L/min per unit at 20 units, 85 at 5), a one- or two-unit machine likely needs more than 85 L/min per unit. The 56 L/min per unit from the Wisconsin paper is a floor with little reserve.
A useful cross-check on horsepower: FAO says each 0.75 kW (1 hp) of motor drives about 280 L/min (9.9 cfm) on oil-lubricated vacuum pumps, and DS64 says 1 hp gives 10 cfm ASME on an oil pump or 7.5 cfm on a water (liquid ring) pump. Horsepower only tells you the pump type's typical output; the flow rating at working vacuum is what to compare.
Why are milking pump ratings so hard to compare?
Because the same pump can be described by numbers that differ by a factor of two or more:
- Free air vs expanded air. FAO's figures are free air: air at standard atmospheric pressure and 20 °C. It notes that some countries quote expanded air, the volume at the vacuum, and that at 50 kPa the expanded-air figure is about double the free-air figure.
- ASME vs NZ. DS64 explains the US version of the same thing: pump capacity may be stated to the American (ASME) or New Zealand (NZ) standard, and one cfm ASME equals two cfm NZ. Both are measured at 15 inHg (about 51 kPa).
- Open flow. General-purpose vacuum pumps, including ours, are often listed by their flow with the inlet open to atmosphere. At milking vacuum the same pump moves much less free air.
How much less? For any positive displacement pump there is a simple upper limit. The pump sweeps roughly the same volume each stroke, but at 50 kPa of vacuum the air it draws in is at about 51 kPa absolute, half of atmospheric. So the free air it moves at 50 kPa is at most about 0.51 times its open-inlet flow, and in practice less, because a piston pump's volumetric efficiency also falls as the pressure ratio rises. At 40 kPa the limit is about 0.61 times; at 44 kPa about 0.57 times (absolute pressure divided by 101.3 kPa, at sea level). Our ultimate pressure vs working vacuum guide explains why curves matter more than end points, and the gauge vs absolute pressure article covers the two scales.
Worked example: a two-unit bucket milker for cows at 50 kPa.
- Floor with little reserve (Wisconsin's 2 scfm per unit, which allows for leaks): 2 × 56 = 112 L/min (4.0 cfm) of free air at 50 kPa.
- Planning figure (FAO, small plants): 2 × 85 = 170 L/min (6.0 cfm), and likely more for a plant this small (see above).
- So look for at least about 110 L/min (3.9 cfm) of free air measured at 50 kPa, and 170 L/min (6.0 cfm) or more if you want a comfortable reserve for attaching units and fall-offs.
- In open-flow terms, divide by 0.51 at the very least: about 220 to 340 L/min (7.8 to 12 cfm) of open flow or more, before the pump's own efficiency loss at vacuum. If a listing gives an ASME rating at 15 inHg, compare it with step 3 directly (3.9 to 6.0 cfm); if it gives an NZ rating, halve it first.
At elevation the atmosphere is thinner, so the same gauge vacuum leaves less absolute pressure and the free-air ratio drops further. See vacuum pump altitude and ambient conditions. To convert flow units, use our CFM to L/min converter.
Which type of vacuum pump is used for milking?
| Type | Where it is used | What to watch |
|---|---|---|
| Oil-lubricated rotary vane | FAO calls rotary oil-sealed pumps the most common type; oil-lubricated high-speed pumps run at 850 to 1,440 rpm | Oil level checked at each milking and belt tension weekly (FAO); belts, motor and oil reclaimer filter (DS64) |
| Water (liquid ring) | Dairy pipeline systems; DS64 rates them at 7.5 cfm per hp vs 10 for oil pumps | Water supply hoses; DS64 warns the pump may burn up if it does not get enough water |
| Oil-free (dry) piston | Small and portable units, equipment makers building compact milkers | Flow at milking vacuum, which open-flow listings do not show; noise; keeping liquid out with a trap |
Whatever the type, FAO recommends an interceptor (trap) of at least 15 L in the main vacuum line next to the pump, with a drain and a float valve that shuts off the vacuum if it fills with liquid. Liquid can damage a dry piston pump's valves and seals, so for an oil-free pump the trap and its float shut-off matter even more. FAO also advises a non-return valve in the exhaust, and running the pump for about 10 minutes after milking to exhaust moisture and let it dry out. Our backflow prevention guide covers traps and check valves in more detail, and the vacuum reservoir sizing guide covers buffer volume, which DS64 says should not be oversized in a pipeline system because extra tanks make the regulator's job harder.
How do you check that the vacuum supply is right?
- Watch the gauge before and after attaching units. FAO says the working vacuum should be constant and the gauge should read the same before and after the clusters go on.
- Listen to the regulator. With all units milking, FAO says you should hear air entering the regulator. No sound means a serious shortage of pump capacity.
- Read the start-up. If the vacuum first rises high and then drops to the working level, FAO says the regulator is sticking and needs cleaning.
- Read the trend. DS64: a rising vacuum points to a dirty regulator; an up-and-down vacuum to a sticking one; a vacuum that drops while the regulator is clean and working means a shortage of pump capacity, from worn belts, a worn pump or new leaks.
- Measure in the right place. DS64 says to read the system vacuum on the main vacuum line, not the pulsator line, which shows pulsation swings.
- Find leaks before buying a bigger pump. DS64's trick: wrap plastic film loosely around pipe joints; it is sucked in wherever a joint leaks. Leakage should stay under 10% of pump capacity.
For a pump that no longer reaches its rating, see how to test a vacuum pump; to turn a pressure-rise test into a leak rate, see the vacuum leak rate guide. A full machine test with a flowmeter is a job for your milking equipment dealer or extension service.
Where does an oil-free piston pump fit, and which HCEM models?
An oil-free piston pump suits small and portable milking machines and equipment makers building them. There is no oil to check at each milking or to carry over into the milk room, and the AC and 12/24/48 V DC versions let a maker build mains-powered or low-voltage units. The limits are just as clear. Our parameter tables give an open-air flow and, in a second "Max. Vacuum" row, a lower flow figure next to −98 kPa. Neither row is a flow at milking vacuum (40 to 50 kPa), and the tables do not give a milking duty rating, so we leave the second row out here. Ask us for data at your working vacuum before you design one in.
Parameter tables of five pumps from our oil-free vacuum pump range, quoted as listed on each product page (store data of 2026-10-31). The last column is our own upper limit from the open flow, as explained above, not a measured value:
| Model | Supply | "Max. Open Air Flow" row, as listed | Power | Noise | Weight | Free air at 50 kPa, at most (our calculation) |
|---|---|---|---|---|---|---|
| HC100A / HC100B | 220 V 50 Hz / 110 V 60 Hz | 45 / 50 L/min (1.59 / 1.77 cfm); −90 kPa | ≤110 / ≤150 W | ≤50 / ≤51 dB(A) | 3.4 kg | 23 / 25 L/min |
| HC100C / D / E | 12 / 24 / 48 V DC | 50 L/min (1.77 cfm); −90 kPa | ≤150 W | ≤56 dB(A) | 2.45 kg | 25 L/min |
| HC280C / D / E | 12 / 24 / 48 V DC | 90 L/min (3.18 cfm); −92 kPa | ≤180 W | ≤58 dB(A) | 4.9 kg | 46 L/min |
| HC680A / HC680B | 220 V 50 Hz / 110 V 60 Hz | 165 / 170 L/min (5.83 / 6.01 cfm); −92 kPa | ≤340 W | ≤60 / ≤61 dB(A) | 9.9 kg | 84 / 86 L/min |
| HC1100A / HC1100B | 220 V 50 Hz / 110 V 60 Hz | 185 / 200 L/min (6.53 / 7.06 cfm); −92 kPa | ≤600 W | ≤68 / ≤70 dB(A) | 17.2 kg | 94 / 101 L/min |
What that means on paper, against the figures above:
- HC100A and HC100D: at most about 23 to 25 L/min of free air at 50 kPa, below the 42 L/min one commercial cow unit uses in steady operation. Not a supply for a cow milking unit.
- HC280D: at most about 46 L/min at 50 kPa, roughly the steady use of one unit and below the 56 L/min that allows for leaks, with nothing left for the regulator or fall-offs. Too small on its own for a cow unit.
- HC680A / HC680B and HC1100A / HC1100B: at most about 84 to 86 and 94 to 101 L/min at 50 kPa, above the 56 L/min floor for one unit and around FAO's 85 L/min per-unit planning figure. Real flow at 50 kPa will be lower than this limit, so treat one unit as the ceiling until you have measured data. A two-unit machine (at least about 110 L/min) needs a larger pump or two pumps.
- Goats: the limit rises at lower vacuum (about 0.61 times open flow at 40 kPa), but none of our sources gives the air use of a goat milking unit, so we do not size goat units here.
For the AC models, the tables list an ambient range of −5 to 40 °C and a thermal switch at 145 ± 5 °C. An unheated barn below −5 °C is outside that range. The DC tables do not list an ambient range; ask us. Tell us your vacuum level, number of units, milking time, supply voltage and installation, and we will tell you what flow data we have at that vacuum, and say plainly if a piston pump is the wrong choice.
For equipment makers we offer custom voltages and logos from 50 units; qualified OEM customers and distributors can apply for samples (subject to review); samples take 10 to 20 days. See the OEM and ODM page.
Common questions
How many CFM does a bucket milker need?
Measured as free air at the working vacuum, a single commercial unit uses about 1.5 cfm (42 L/min) in steady operation, and the Wisconsin paper suggests 2 cfm (56 L/min) per unit to allow for leaks. FAO's planning figure for small plants is 85 L/min (3.0 cfm) per unit at 50 kPa, and likely more for one or two units. Keep leaks under 10% of pump capacity (DS64) and allow for attaching units. Check which rating a listing uses before comparing: open flow, ASME at 15 inHg, or NZ (twice ASME).
What vacuum should a goat milking machine run at?
The 2021 Murciano-Granadina study summarizes recommended settings for goats as 36 to 48 kPa (10.6 to 14.2 inHg) system vacuum, 70 to 120 pulsations per minute and a 60% ratio. The right value within that range depends on breed and line height, so take it from your equipment supplier.
Is a higher vacuum better?
No. FAO notes that higher vacuum milks faster but leaves more strippings, and DS64 reports teat-end damage above 15 inHg (about 51 kPa). A pump that can pull much deeper than milking needs is fine, as long as the regulator holds the set level.
Why does my vacuum drop when I attach the units?
Either the pump lacks capacity at the working vacuum, the system leaks, or the regulator is dirty. FAO's test: with all units on, you should still hear air entering the regulator. If you do not, the pump is too small or leaks are eating its capacity (DS64).
Building a portable milker or a vacuum supply for one? Send us the animals, vacuum level, number of units, supply voltage and how long the pump runs per milking. Our engineers will suggest a model, share the flow data we have at that vacuum, and tell you if it is not the right fit.
Sources
All read 2026-11-08.
- FAO: Milking, milk production hygiene and udder health, chapter 2: Milking machines and equipment.
- University of Florida IFAS Extension: DS64, Milking Management III: The Vacuum Pump Milking System (D. R. Bray), archival copy, PDF.
- D. J. Reinemann and G. A. Mein, University of Wisconsin-Madison: Sizing Vacuum Pumps for Cleaning Milking Systems, National Mastitis Council 1995, PDF.
- G. Romero and co-authors: Effect of Vacuum Level and Pulsation Parameters on Milking Efficiency and Animal Welfare of Murciano-Granadina Goats Milked in Mid-Line and Low-Line Milking Machines, Animals 12(1):40, 2021.
- NIST: Guide to the SI, Appendix B.9.