Skip to product information
1 of 6

HC580A-2 Oilless Vacuum Pump | 340W, 120 L/min, ≤60dB(A)

HC580A-2 Oilless Vacuum Pump | 340W, 120 L/min, ≤60dB(A)

VACUUM PUMP Request a Quote

Oil-Free Design

Zero oil contamination for clean air output

Continuous Duty

24/7 operation rated for industrial use

CE Certified

Complies with international safety standards

OEM/ODM Available

Customization for your specific requirements

View full details

Why Choose the HC580A-2 Oilless Vacuum Pump

When a lab technician prepares sensitive chromatography samples, introducing hydrocarbon vapors from a standard lubricated pump can compromise the entire analysis, leading to false readings and wasted materials. The HC580A-2 oilless vacuum pump eliminates this risk entirely by utilizing a dry-running mechanical design that guarantees a completely clean, uncontaminated vacuum path. This precise engineering not only protects critical laboratory processes but also drastically reduces maintenance intervals by removing the need for oil changes, oil disposal, and exhaust filter replacements. Built for continuous duty, this pump is designed to operate reliably over long shifts without experiencing thermal degradation. The integration of a highly efficient 340W motor ensures that the unit draws minimal electrical current while delivering maximum pneumatic performance. For engineers tasked with specifying components for complex machinery, this pump provides a stable, predictable vacuum source that integrates easily into broader systems.

  • Motor Power: 340W, engineered for efficient electrical consumption during continuous operation.
  • Flow Rate: 120 L/min, providing rapid evacuation and consistent suction capacity for demanding applications.
  • Acoustic Performance: ≤60dB(A) noise level, designed specifically for quiet operation in laboratories and medical facilities.
  • Lubrication Type: 100% oil-free design, guaranteeing a clean vacuum path with zero hydrocarbon emissions.
  • Operating Cycle: Rated for continuous duty, supporting demanding 24/7 industrial and clinical schedules.
  • Regulatory Certifications: CE, RoHS, and ISO 9001 compliant for immediate integration into global markets.

Key Technical Specifications

Specification Value
Model Number HC580A-2
Pump Type Oilless Vacuum Pump
Power Consumption 340W
Maximum Flow Rate 120 L/min
Noise Level ≤60dB(A)
Duty Cycle Continuous Duty
Lubrication Oil-Free / Dry Running
Certifications CE, RoHS, ISO 9001

Applications & Industries

The HC580A-2 is highly specified for laboratory and medical environments where air purity and low acoustic profiles are strict requirements. In analytical chemistry applications such as gas chromatography, mass spectrometry, and vacuum filtration, the completely oil-free design prevents sample contamination and protects sensitive sensor equipment. For medical suction devices, the steady 120 L/min flow rate provides reliable, consistent aspiration capabilities necessary for patient care. Furthermore, the ≤60dB(A) noise profile ensures that the pump can be integrated directly into point-of-care equipment, dental chairs, or diagnostic workstations without causing acoustic fatigue for medical professionals or patients.

In the packaging sector, this pump serves as a dependable vacuum source for automated tray sealers, vacuum bagging machines, and modified atmosphere packaging (MAP) systems. The 340W motor provides sufficient torque and continuous power to maintain precise vacuum levels during rapid, high-volume cycling processes. Because it requires absolutely no lubricating oil, processing facilities handling food, pharmaceuticals, or sensitive electronic components can deploy the HC580A-2 without risking aerosolized oil contaminating the packaging line, the cleanroom environment, or the end products themselves.

For pick-and-place automation and robotics, consistent vacuum generation is critical for the reliable operation of end-of-arm tooling and suction cups. The continuous duty rating of the HC580A-2 allows it to run across multiple shifts in high-speed manufacturing environments across Europe, North America, and Southeast Asia. Whether the application involves handling delicate silicon wafers in semiconductor manufacturing, assembling consumer electronics, or sorting lightweight plastics in logistics centers, the pump delivers the necessary suction force. It achieves this while minimizing the downtime typically associated with pneumatic maintenance, keeping production lines moving efficiently.

Certifications & Compliance

Navigating international trade and equipment compliance requires components that meet recognized global standards. For procurement engineers and OEM manufacturers exporting to or operating within the European Economic Area, the HC580A-2 carries full CE marking. This certification confirms that the pump meets strict European safety, health, and environmental protection directives. Additionally, RoHS compliance guarantees that the pump's internal components, wiring, and housing are manufactured without restricted hazardous materials such as lead, mercury, cadmium, or hexavalent chromium. This significantly simplifies the regulatory approval process for your final equipment, ensuring your assembled products can cross international borders without facing compliance delays or customs rejections.

At the manufacturing level, HCEM Pump operates under a certified ISO 9001 quality management system. For B2B buyers and supply chain managers, this translates directly to consistent manufacturing tolerances, rigorous end-of-line testing, and highly reliable batch-to-batch performance. By sourcing an ISO 9001 certified oilless vacuum pump, technical managers can confidently integrate this component into their supply chain, knowing that every single unit delivered will match the documented 340W, 120 L/min, and ≤60dB(A) specifications. This level of quality assurance minimizes the risk of component failure in the field and protects the reputation of the OEM brands that utilize HCEM pumps in their machinery.

Frequently Asked Questions

What is the maintenance schedule for the HC580A-2 given its continuous duty rating?

Because the HC580A-2 is an oilless vacuum pump, it requires significantly less maintenance than standard lubricated alternatives. There is no oil to check, top up, or replace, and no hazardous waste oil to dispose of. Maintenance is generally limited to periodic inspection and replacement of the intake air filters. Keeping the filters clean ensures that the 120 L/min flow rate is not restricted by particulate buildup, which could otherwise force the 340W motor to work harder and increase wear.

Is the HC580A-2 suitable for pick-and-place automation systems?

Yes. The pump is specifically engineered for continuous duty, making it highly effective for fast-paced pick-and-place automation. The 340W motor provides stable, continuous vacuum generation required for suction cups and pneumatic end effectors. Furthermore, the oil-free design ensures that no exhaust mist contaminates the automation cell, the optical sensors, or the handled components, which is critical in electronics manufacturing and packaging.

Does the pump meet the requirements for medical suction applications?

The HC580A-2 is frequently integrated into medical suction equipment and clinical devices. Its ≤60dB(A) noise level is quiet enough for patient-facing clinical settings, preventing acoustic fatigue for healthcare workers. The CE and RoHS certifications assist medical device manufacturers in meeting their own strict regulatory compliance standards. Most importantly, the dry, clean vacuum operation is mandatory for preventing airborne contamination in sterile healthcare environments.

What are the installation requirements for the HC580A-2 regarding ventilation and mounting?

While the 340W motor is highly efficient, proper ventilation is required to dissipate heat during continuous duty operation. The pump should be installed in a clean, dry area with adequate ambient airflow around the motor housing. Restricting airflow can increase the operating temperature, which may affect the long-term performance of the internal components. It is recommended to mount the pump on vibration-damping pads to maintain the low ≤60dB(A) noise profile and prevent resonance from transferring to the equipment chassis.

Download the complete technical datasheet for specifications and performance curves.

No video available for this product.

Get a Quote

Request a Quote for This Product

Tell us your quantity and application. We will respond within 24 hours with pricing and availability.

  • Response within 24 hours
  • Free samples for qualified buyers
  • OEM / ODM customization available

Translation missing: en.By submitting you agree to our Translation missing: en.Privacy Policy.