Skip to product information
1 of 5

HC210 Medical Oxygenation Pump | ≤230W, ≥50L/min, CE MDR 2017/745

HC210 Medical Oxygenation Pump | ≤230W, ≥50L/min, CE MDR 2017/745

OXYGEN CONCENTRATOR COMPRESSOR Request a Quote

Oil-Free Design

Zero oil contamination for clean air output

Continuous Duty

24/7 operation rated for industrial use

CE Certified

Complies with international safety standards

OEM/ODM Available

Customization for your specific requirements

View full details
_DESCRIPTION: For a home care equipment manufacturer needing CE MDR-compliant pumps for portable oxygen devices, component reliability dictates patient safety. The HC210 medical oxygenation pump is engineered specifically for these critical environments. Operating continuously on a 24-hour duty cycle, this oil-free pump delivers a dependable flow rate of ≥50L/min at 140Kpa while consuming just ≤230W of power. With operating noise kept at a quiet ≤52dB(A), it is highly suitable for patient-proximal settings. Certified to CE MDR 2017/745 and ISO 13485 standards, the HC210 integrates easily into systems for oxygen concentrators, hospital respiratory equipment, and medical-grade air supply lines. Available in both 220V and 110V configurations, this pump provides equipment engineers with a proven, quiet, and highly efficient pneumatic solution to ensure consistent air delivery and simplify global regulatory compliance for medical OEMs. LONG_DESCRIPTION:

Why Choose the HC210 Medical Oxygenation Pump

For a home care equipment manufacturer needing CE MDR-compliant pumps for portable oxygen devices, selecting the right pneumatic compressor is a matter of strict safety and clinical efficacy. Patient outcomes depend on uninterrupted, clean air delivery day and night. The HC210 medical oxygenation pump answers this exact demand by providing an oil-free, continuous 24-hour duty cycle that delivers pure air without any risk of particulate or hydrocarbon contamination. Designed specifically for integration into life-supporting and therapeutic respiratory systems, this unit ensures high-flow performance while maintaining strict acoustic limits. By keeping noise to a minimum and maximizing air output, OEMs can build quieter, more efficient medical devices for both clinical facilities and home care environments.

  • Power Efficiency: Operates at an economical ≤230W at rated pressure while maintaining high compression output.
  • Consistent Flow and Pressure: Achieves a dependable air flow rate of ≥50L/min at a rated pressure of 140Kpa through a pressure parallel flow configuration.
  • Quiet Operation: Generates minimal acoustic disturbance with noise levels strictly restricted to ≤52dB(A) for patient comfort.
  • Continuous Duty Lifespan: Engineered for a continuous 24-hour duty cycle to maximize operational lifespan, featuring automatic thermal protection at 145±5℃.
  • Regulatory Assurances: Fully compliant with CE MDR 2017/745 and manufactured under ISO 13485 quality management systems.
  • Environmental Versatility: Functions safely and reliably within a broad operating ambient temperature range of -5 to 40℃.

Key Technical Specifications

Specification Value (HC210A-50/1.4 / HC210B-50/1.4)
Head Configuration Pressure parallel flow
Voltage 220V/50Hz/1 / 110V/60Hz/1
Noise ≤52dB(A)
Power at rated pressure ≤230W
Air flow rate at rated pressure ≥50L/min @ 140Kpa
Speed at rated pressure 1400 rpm / 1700 rpm
Dimension 198*96*146 mm
Installation size 136*70 mm
Net Weight 4.3 kg
Operating ambient temperature -5 to 40℃
Thermal protection 145±5℃
Motor insulation class F
Capacitor value 8μF / 15μF

Applications & Industries

The HC210 is primarily designed as the core pneumatic driver for high-capacity oxygen concentrators. In both clinical and home settings, these machines require a steady, oil-free medical-grade air supply to pass through zeolite sieve beds, which strip nitrogen and deliver purified oxygen directly to the patient. The medical oxygenation pump's flow rate of ≥50L/min at 140Kpa ensures that 5-liter to 10-liter concentrator models receive the necessary intake volume and driving pressure to function efficiently over a continuous 24-hour duty cycle without pressure drops.

Beyond concentrators, this unit serves as an essential internal component in broader hospital respiratory equipment, including high-flow nasal cannula systems and continuous positive airway pressure (CPAP) or bi-level positive airway pressure (BiPAP) machines. The low acoustic profile of ≤52dB(A) is highly critical in these applications, as hospital wards and intensive care units enforce strict noise limits to promote restful patient recovery. Its specific installation footprint of 136x70 mm and manageable net weight of 4.3 kg allows biomedical engineers to easily integrate the pump into the tight chassis spaces typical of modern bedside equipment.

Additionally, the pump acts as a reliable source for medical-grade air supply in centralized clinic distribution panels or mobile dental carts. Because the HC210 operates entirely without oil lubrication, it effectively eliminates the risk of hydrocarbon vapor contamination in the patient airstream. This mechanical design ensures all generated compressed air remains completely safe for direct inhalation, nebulizer therapies, or for driving delicate surgical tools that require clean, dry compressed air.

Certifications & Compliance

Navigating the global medical device market requires strict, documented adherence to international safety and quality standards. The HC210 simplifies this complex regulatory pathway for OEMs because it is manufactured under fully audited ISO 13485 quality management systems. This specific certification guarantees that every pump is produced in a facility dedicated to the strict material traceability, risk management, and consistent manufacturing processes required specifically for medical device components. Manufacturers can source this pump knowing the supply chain and production quality meet rigorous clinical expectations from day one.

Furthermore, the pump aligns strictly with CE MDR 2017/745 requirements, which is an essential factor for companies distributing medical equipment within the European Economic Area. By incorporating a pump component that already meets these high thresholds for clinical safety, biological compatibility, and electrical performance, medical device manufacturers can significantly reduce their own systemic testing times and technical documentation burdens. This compliance ensures reliable market access and reinforces end-user trust in the final therapeutic product's safety.

Frequently Asked Questions

What are the electrical requirements and specific voltage options for this medical oxygenation pump?

The HC210 series is manufactured in two distinct electrical configurations to support global manufacturing requirements. The HC210A-50/1.4 model operates on a 220V/50Hz power supply using an 8μF capacitor, functioning at a motor speed of 1400 rpm. The HC210B-50/1.4 model operates on a 110V/60Hz power supply using a larger 15μF capacitor, running at a speed of 1700 rpm. Both configurations feature a safe Class F motor insulation rating and consume ≤230W of power at their maximum rated pressure of 140Kpa.

Is the HC210 pump suitable for hospital respiratory equipment that requires non-stop continuous operation?

Yes, this pump is engineered specifically for a continuous 24-hour duty cycle, making it highly suitable for life-support ventilators, continuous flow concentrators, and other hospital respiratory equipment. To proactively protect the motor and internal components during continuous, heavy-duty use, the unit includes an integrated thermal protection switch that automatically activates if the internal operating temperature reaches 145±5℃. It also functions safely and reliably in varying ambient facility temperatures ranging from -5 to 40℃.

How does this specific model ensure the purity of the medical-grade air supply?

The HC210 utilizes a completely oil-free pneumatic compression mechanism. This specific mechanical design prevents any lubricating oils, greases, or hydrocarbon vapors from entering the internal air path, ensuring that the final output remains clean and uncontaminated. This is a strict operational requirement for applications such as oxygen concentrators and direct patient ventilation systems, where medical-grade air purity is both legally mandated by CE MDR standards and medically required for patient safety.

Download the complete technical datasheet for specifications and performance curves.

No video available for this product.

Get a Quote

Request a Quote for This Product

Tell us your quantity and application. We will respond within 24 hours with pricing and availability.

  • Response within 24 hours
  • Free samples for qualified buyers
  • OEM / ODM customization available

Translation missing: en.By submitting you agree to our Translation missing: en.Privacy Policy.