{"product_id":"ht120z-01-dc-medical-oxygenation-pump","title":"HT120Z-01 Medical Oxygenation Pump | 12V, 42L\/min, CE MDR","description":"\u003ch2\u003eWhy Choose the HT120Z-01 Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003eWhen a hospital biomedical engineer is tasked with specifying pumps for a new oxygen concentrator production line, component failure is simply not an option. They require a continuous, contamination-free air supply that operates quietly within a sensitive clinical environment. The engineering behind the HT120Z-01 answers this exact demand. By utilizing a strictly oil-free mechanism and supporting a continuous 24-hour duty cycle, this model is designed specifically for the rigorous demands of medical applications. Medical equipment manufacturers face strict pressures to deliver devices that run constantly without overheating or degrading in performance. This pump addresses those challenges directly, providing steady pneumatic power that medical professionals can trust during critical patient interventions. The compact nature of the unit combined with its impressive output metrics makes it a highly versatile component for modern healthcare hardware.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower efficiency:\u003c\/strong\u003e Consumes ≤120W of power at its rated pressure, ensuring the overall medical device maintains sensible power draw limits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-capacity output:\u003c\/strong\u003e Delivers an impressive air flow rate of 42L\/min @1.4bar, providing substantial volume for respiratory needs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuiet clinical operation:\u003c\/strong\u003e Maintains a noise level of ≤42dB(A), preventing auditory fatigue for both patients and healthcare workers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegulatory compliance:\u003c\/strong\u003e Holds critical CE MDR 2017\/745 and ISO 13485 certifications for immediate global market readiness.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtreme temperature resilience:\u003c\/strong\u003e Engineered to operate safely and consistently in environments ranging from -40℃ to +40℃.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaintenance-friendly design:\u003c\/strong\u003e Weighing just 1.1kg with a footprint of 129×70×118mm, it simplifies integration and servicing for technicians.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003eHT120Z-01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHead Configuration\u003c\/td\u003e\n      \u003ctd\u003ePressure parallel flow\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVoltage\u003c\/td\u003e\n      \u003ctd\u003e12V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNoise\u003c\/td\u003e\n      \u003ctd\u003e≤42dB(A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower at rated pressure\u003c\/td\u003e\n      \u003ctd\u003e≤120W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAir flow rate at rated pressure\u003c\/td\u003e\n      \u003ctd\u003e42L\/min @1.4bar\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpeed at rated pressure\u003c\/td\u003e\n      \u003ctd\u003e2800rpm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimension\u003c\/td\u003e\n      \u003ctd\u003e129×70×118mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTemperature\u003c\/td\u003e\n      \u003ctd\u003e-40℃-+40 ℃\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet weight\u003c\/td\u003e\n      \u003ctd\u003e1.1kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HT120Z-01 medical oxygenation pump is engineered specifically for manufacturers of advanced medical devices requiring consistent and precise pneumatic performance. Its primary application is within high-capacity oxygen concentrators. In these vital systems, the internal pump must constantly draw in ambient room air and push it forcefully through zeolite sieve beds at highly specific pressures to separate nitrogen from oxygen. The reliable flow rate of 42L\/min at a pressure of 1.4bar makes this specific model highly suitable for standard 5-liter to 10-liter clinical oxygen concentrators. This continuous flow ensures that patients suffering from chronic obstructive pulmonary disease (COPD) or severe respiratory distress receive a continuous, precise volume of concentrated oxygen therapy without mechanical interruption.\u003c\/p\u003e\n\n\u003cp\u003eBeyond standard oxygen concentration, this pump integrates effectively into diverse hospital respiratory equipment. Ventilators, as well as continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BiPAP) machines, depend entirely on reliable baseline pressure generation to keep patient airways open. The pressure parallel flow head configuration and the steady 2800rpm motor speed provide the necessary pneumatic foundation required for these life-saving respiratory support devices. Additionally, because the unit operates quietly at ≤42dB(A), it does not disturb the recovery environment in intensive care units, neonatal wards, or sleep therapy centers. Low noise emission is a strict requirement for any bedside medical machinery, ensuring patients can rest comfortably while receiving care.\u003c\/p\u003e\n\n\u003cp\u003eFacilities relying on dedicated medical-grade air supply networks also utilize this compact pump for localized or portable medical air generation. Dental clinics, localized nebulizer stations, and minor outpatient surgical theaters require compressed air that is completely free of oil particulate and environmental moisture. The oil-free mechanical design of the HT120Z-01 guarantees that the output air remains pure and safe for direct patient inhalation or for driving delicate surgical tools. With a highly compact dimension of 129×70×118mm and a net weight of just 1.1kg, original equipment manufacturers can easily install this unit into portable medical carts, emergency transport ventilators in ambulances, and backup air supply units without adding unnecessary bulk.\u003c\/p\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003eNavigating the complex and shifting landscape of medical device regulations requires starting with foundational components that already meet strict, verifiable standards. The HT120Z-01 proudly holds the CE MDR 2017\/745 certification, which is legally mandatory for any medical devices sold within the European Economic Area. The modern Medical Device Regulation (MDR) ensures exceptionally high standards of clinical quality and safety, focusing heavily on clinical evaluation data, supply chain traceability, and extensive post-market surveillance. By actively incorporating a pump that already aligns with these stringent MDR guidelines, device manufacturers significantly reduce their own internal compliance burden, minimize documentation delays, and accelerate their time to market in highly regulated European territories.\u003c\/p\u003e\n\n\u003cp\u003eFurthermore, the dedicated manufacturing facilities producing the HT120Z-01 successfully maintain ISO 13485 certification. This internationally recognized and respected standard specifies exact requirements for a comprehensive quality management system. It dictates that an organization needs to prove its ability to provide medical devices and related services that consistently meet both customer expectations and applicable statutory regulatory requirements. For B2B procurement officers and lead engineers, this ISO certification means every single pump coming off the assembly line offers predictable reliability, has undergone rigorous defect testing, and comes with comprehensive production documentation. This guarantees that the final hospital equipment performs safely and predictably during critical patient care situations.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat are the power requirements and environmental operating conditions for the HT120Z-01?\u003c\/h3\u003e\n\u003cp\u003eThe HT120Z-01 requires a standard 12V DC power supply to function. When operating at its specified rated pressure of 1.4bar, the unit is highly efficient, consuming ≤120W of power while the internal motor runs at a constant speed of 2800rpm. From an environmental standpoint, the pump is highly adaptable to various storage and operational climates, functioning safely in ambient temperatures ranging from a freezing -40℃ all the way up to +40℃.\u003c\/p\u003e\n\n\u003ch3\u003eIs the HT120Z-01 suitable for integration into portable hospital respiratory equipment?\u003c\/h3\u003e\n\u003cp\u003eYes, this specific medical oxygenation pump is highly appropriate for portable and mobile hospital applications. It features a very compact spatial footprint, measuring just 129×70×118mm, and possesses a highly manageable net weight of only 1.1kg. This combination of low weight and small volume makes it easy for engineers to integrate into mobile oxygen concentrators, emergency transport ventilators, and battery-operated carts where internal space and total device weight are critical design constraints.\u003c\/p\u003e\n\n\u003ch3\u003eDoes this pump require ongoing oil lubrication to maintain its continuous 24-hour duty cycle?\u003c\/h3\u003e\n\u003cp\u003eNo, the HT120Z-01 features a strictly oil-free mechanical design. This specific engineering choice is absolutely necessary to ensure the continuous production of medical-grade air purity, completely preventing any aerosolized oil contaminants or lubricants from reaching the patient's respiratory tract. It is heavily engineered to handle a continuous 24-hour duty cycle safely and efficiently without ever requiring routine oil changes or lubrication maintenance from hospital staff.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154805240046,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/Company-Profile-16.jpg?v=1781601316","url":"https:\/\/hcempump.com\/products\/ht120z-01-dc-medical-oxygenation-pump","provider":"Hcem","version":"1.0","type":"link"}