{"title":"OXYGEN CONCENTRATOR COMPRESSOR","description":null,"products":[{"product_id":"hc30m","title":"HC30M Oilless Air Pump | 19W, CE, 24h Continuous Duty","description":"\u003ch2\u003eWhy Choose the HC30M Oilless AC Air Pump\u003c\/h2\u003e\n\u003cp\u003eImagine a lab manager frustrated by oil contamination shutting down a sensitive analytical instrument right in the middle of a critical testing cycle. This common failure not only ruins expensive samples but also demands extensive cleaning and recalibration of the entire pneumatic system. The HC30M oilless air pump removes this variable entirely by utilizing an advanced, completely dry compression mechanism. By ensuring zero lubricant carryover, this pump protects sensitive downstream equipment and guarantees the purity of the air supply in strict operational environments.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e Highly efficient 19W operation minimizes energy draw in continuous applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAcoustic Performance:\u003c\/strong\u003e Operates at a low noise level of ≤70dB, suitable for quiet laboratory and medical environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperational Lifespan:\u003c\/strong\u003e Engineered for extreme longevity, offering 10,000 to 70,000 hours of functional life depending on application parameters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuty Cycle:\u003c\/strong\u003e Capable of 24h continuous duty, ensuring reliable performance in always-on industrial and medical systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLubrication:\u003c\/strong\u003e 100% oil-free design prevents system contamination and eliminates routine oil maintenance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Fully certified to CE, ISO 9001, and RoHS standards for direct integration into global OEM products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003eHC30M\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePump Technology\u003c\/td\u003e\n      \u003ctd\u003eOilless AC Air Pump\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd\u003e19W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDuty Cycle\u003c\/td\u003e\n      \u003ctd\u003e24h Continuous Duty\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNoise Level\u003c\/td\u003e\n      \u003ctd\u003e≤70dB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExpected Lifespan\u003c\/td\u003e\n      \u003ctd\u003e10,000 - 70,000 hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCertifications\u003c\/td\u003e\n      \u003ctd\u003eCE, ISO 9001, RoHS\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HC30M oilless air pump is engineered to meet the strict demands of laboratory instruments. In analytical chemistry and clinical diagnostics, equipment such as gas chromatographs, mass spectrometers, and automated liquid handlers require absolute air purity. The 19W AC motor provides a steady, continuous flow without the risk of introducing microscopic oil droplets into the system. This guarantees that test results remain accurate and sensitive sensors are not degraded over time. The 24-hour continuous duty cycle ensures that high-throughput laboratories can run overnight batches without fear of pump failure or pressure drops, maintaining the integrity of time-sensitive experiments and long-term studies.\u003c\/p\u003e\n\u003cp\u003eIn the medical devices sector, patient safety and equipment reliability are non-negotiable. The HC30M is frequently specified by OEM buyers for integration into respiratory care devices, medical aspiration systems, and pneumatic compression therapy units. The low noise output of ≤70dB is critical in these settings, as it prevents auditory fatigue for healthcare professionals and maintains a comfortable environment for patients recovering in hospital wards or undergoing treatment in clinical settings. Furthermore, the extensive lifespan ranging from 10,000 to 70,000 hours significantly reduces the frequency of scheduled maintenance, lowering the total cost of ownership for hospitals and clinics while minimizing disruptive equipment downtime.\u003c\/p\u003e\n\u003cp\u003eBeyond scientific and medical fields, this pump serves vital roles in food packaging and industrial automation. Food packaging machinery utilizes pneumatic systems to handle delicate products, seal containers, and manage modified atmosphere packaging (MAP) processes. An oil-free air source is legally and functionally required to prevent food contamination and adhere to strict hygiene standards. In industrial automation, the HC30M actuates small pneumatic cylinders, vacuum grippers, and sorting mechanisms. The strict adherence to ISO 9001 manufacturing protocols ensures that every pump delivers consistent, reliable performance on fast-paced assembly lines, reducing the risk of unexpected production halts.\u003c\/p\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003eFor procurement engineers and technical managers, regulatory compliance is a primary factor when selecting internal components for OEM equipment. The HC30M oilless air pump carries CE certification, indicating strict conformity with health, safety, and environmental protection standards for products sold within the European Economic Area (EEA). This allows European manufacturers, as well as international exporters, to integrate the pump into their systems without facing regulatory friction during the final product certification process. The CE mark serves as a clear indicator of the pump's electrical and mechanical safety.\u003c\/p\u003e\n\u003cp\u003eAdditionally, HCEM Pump manufactures the HC30M under strict ISO 9001 quality management systems. This certification guarantees that our production facilities maintain consistent quality control, resulting in predictable batch-to-batch reliability and precise adherence to the stated 19W power and ≤70dB noise specifications. The pump is also fully RoHS compliant, meaning it is manufactured without the use of hazardous substances like lead, mercury, or cadmium. This compliance is essential for electronics and machinery manufacturers exporting to the European Union, North America, and other markets with stringent environmental and electronic waste regulations, ensuring your final product remains legally compliant and environmentally responsible.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat maintenance is required for the HC30M during its 10,000 to 70,000-hour lifespan?\u003c\/h3\u003e\n\u003cp\u003eBecause the HC30M is a completely oilless air pump, it requires zero lubrication maintenance. There are no oil levels to check, no oil to change, and no oil filters to replace. Maintenance is typically limited to periodic inspection of external air intake filters to ensure they are clear of dust and debris, maximizing the efficiency of the 19W motor and maintaining the ≤70dB noise profile.\u003c\/p\u003e\n\n\u003ch3\u003eIs the HC30M suitable for continuous use in industrial automation?\u003c\/h3\u003e\n\u003cp\u003eYes, the HC30M is specifically rated for 24h continuous duty. The thermal management of the AC motor allows it to run non-stop without overheating, making it an excellent choice for automated assembly lines, continuous packaging operations, and other industrial applications that operate on a 24\/7 production schedule.\u003c\/p\u003e\n\n\u003ch3\u003eDoes the CE and RoHS certification apply to the entire pump assembly?\u003c\/h3\u003e\n\u003cp\u003eYes, the complete HC30M unit is CE marked and RoHS compliant. OEM buyers can confidently integrate this pump into their laboratory instruments or medical devices knowing that the component will not introduce hazardous materials into their supply chain or complicate their own CE marking process for the final assembled product.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154802815214,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/E4_B8_BB_E5_9B_BE.webp?v=1781601267"},{"product_id":"ht120z-01-dc-medical-oxygenation-pump","title":"HT120Z-01 Medical Oxygenation Pump | 12V, 42L\/min, CE MDR","description":"\u003ch2\u003eWhy Choose the HT120Z-01 Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003eWhen a hospital biomedical engineer is tasked with specifying pumps for a new oxygen concentrator production line, component failure is simply not an option. They require a continuous, contamination-free air supply that operates quietly within a sensitive clinical environment. The engineering behind the HT120Z-01 answers this exact demand. By utilizing a strictly oil-free mechanism and supporting a continuous 24-hour duty cycle, this model is designed specifically for the rigorous demands of medical applications. Medical equipment manufacturers face strict pressures to deliver devices that run constantly without overheating or degrading in performance. This pump addresses those challenges directly, providing steady pneumatic power that medical professionals can trust during critical patient interventions. The compact nature of the unit combined with its impressive output metrics makes it a highly versatile component for modern healthcare hardware.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower efficiency:\u003c\/strong\u003e Consumes ≤120W of power at its rated pressure, ensuring the overall medical device maintains sensible power draw limits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-capacity output:\u003c\/strong\u003e Delivers an impressive air flow rate of 42L\/min @1.4bar, providing substantial volume for respiratory needs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuiet clinical operation:\u003c\/strong\u003e Maintains a noise level of ≤42dB(A), preventing auditory fatigue for both patients and healthcare workers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegulatory compliance:\u003c\/strong\u003e Holds critical CE MDR 2017\/745 and ISO 13485 certifications for immediate global market readiness.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtreme temperature resilience:\u003c\/strong\u003e Engineered to operate safely and consistently in environments ranging from -40℃ to +40℃.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaintenance-friendly design:\u003c\/strong\u003e Weighing just 1.1kg with a footprint of 129×70×118mm, it simplifies integration and servicing for technicians.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003eHT120Z-01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHead Configuration\u003c\/td\u003e\n      \u003ctd\u003ePressure parallel flow\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVoltage\u003c\/td\u003e\n      \u003ctd\u003e12V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNoise\u003c\/td\u003e\n      \u003ctd\u003e≤42dB(A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower at rated pressure\u003c\/td\u003e\n      \u003ctd\u003e≤120W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAir flow rate at rated pressure\u003c\/td\u003e\n      \u003ctd\u003e42L\/min @1.4bar\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpeed at rated pressure\u003c\/td\u003e\n      \u003ctd\u003e2800rpm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimension\u003c\/td\u003e\n      \u003ctd\u003e129×70×118mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTemperature\u003c\/td\u003e\n      \u003ctd\u003e-40℃-+40 ℃\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet weight\u003c\/td\u003e\n      \u003ctd\u003e1.1kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HT120Z-01 medical oxygenation pump is engineered specifically for manufacturers of advanced medical devices requiring consistent and precise pneumatic performance. Its primary application is within high-capacity oxygen concentrators. In these vital systems, the internal pump must constantly draw in ambient room air and push it forcefully through zeolite sieve beds at highly specific pressures to separate nitrogen from oxygen. The reliable flow rate of 42L\/min at a pressure of 1.4bar makes this specific model highly suitable for standard 5-liter to 10-liter clinical oxygen concentrators. This continuous flow ensures that patients suffering from chronic obstructive pulmonary disease (COPD) or severe respiratory distress receive a continuous, precise volume of concentrated oxygen therapy without mechanical interruption.\u003c\/p\u003e\n\n\u003cp\u003eBeyond standard oxygen concentration, this pump integrates effectively into diverse hospital respiratory equipment. Ventilators, as well as continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BiPAP) machines, depend entirely on reliable baseline pressure generation to keep patient airways open. The pressure parallel flow head configuration and the steady 2800rpm motor speed provide the necessary pneumatic foundation required for these life-saving respiratory support devices. Additionally, because the unit operates quietly at ≤42dB(A), it does not disturb the recovery environment in intensive care units, neonatal wards, or sleep therapy centers. Low noise emission is a strict requirement for any bedside medical machinery, ensuring patients can rest comfortably while receiving care.\u003c\/p\u003e\n\n\u003cp\u003eFacilities relying on dedicated medical-grade air supply networks also utilize this compact pump for localized or portable medical air generation. Dental clinics, localized nebulizer stations, and minor outpatient surgical theaters require compressed air that is completely free of oil particulate and environmental moisture. The oil-free mechanical design of the HT120Z-01 guarantees that the output air remains pure and safe for direct patient inhalation or for driving delicate surgical tools. With a highly compact dimension of 129×70×118mm and a net weight of just 1.1kg, original equipment manufacturers can easily install this unit into portable medical carts, emergency transport ventilators in ambulances, and backup air supply units without adding unnecessary bulk.\u003c\/p\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003eNavigating the complex and shifting landscape of medical device regulations requires starting with foundational components that already meet strict, verifiable standards. The HT120Z-01 proudly holds the CE MDR 2017\/745 certification, which is legally mandatory for any medical devices sold within the European Economic Area. The modern Medical Device Regulation (MDR) ensures exceptionally high standards of clinical quality and safety, focusing heavily on clinical evaluation data, supply chain traceability, and extensive post-market surveillance. By actively incorporating a pump that already aligns with these stringent MDR guidelines, device manufacturers significantly reduce their own internal compliance burden, minimize documentation delays, and accelerate their time to market in highly regulated European territories.\u003c\/p\u003e\n\n\u003cp\u003eFurthermore, the dedicated manufacturing facilities producing the HT120Z-01 successfully maintain ISO 13485 certification. This internationally recognized and respected standard specifies exact requirements for a comprehensive quality management system. It dictates that an organization needs to prove its ability to provide medical devices and related services that consistently meet both customer expectations and applicable statutory regulatory requirements. For B2B procurement officers and lead engineers, this ISO certification means every single pump coming off the assembly line offers predictable reliability, has undergone rigorous defect testing, and comes with comprehensive production documentation. This guarantees that the final hospital equipment performs safely and predictably during critical patient care situations.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat are the power requirements and environmental operating conditions for the HT120Z-01?\u003c\/h3\u003e\n\u003cp\u003eThe HT120Z-01 requires a standard 12V DC power supply to function. When operating at its specified rated pressure of 1.4bar, the unit is highly efficient, consuming ≤120W of power while the internal motor runs at a constant speed of 2800rpm. From an environmental standpoint, the pump is highly adaptable to various storage and operational climates, functioning safely in ambient temperatures ranging from a freezing -40℃ all the way up to +40℃.\u003c\/p\u003e\n\n\u003ch3\u003eIs the HT120Z-01 suitable for integration into portable hospital respiratory equipment?\u003c\/h3\u003e\n\u003cp\u003eYes, this specific medical oxygenation pump is highly appropriate for portable and mobile hospital applications. It features a very compact spatial footprint, measuring just 129×70×118mm, and possesses a highly manageable net weight of only 1.1kg. This combination of low weight and small volume makes it easy for engineers to integrate into mobile oxygen concentrators, emergency transport ventilators, and battery-operated carts where internal space and total device weight are critical design constraints.\u003c\/p\u003e\n\n\u003ch3\u003eDoes this pump require ongoing oil lubrication to maintain its continuous 24-hour duty cycle?\u003c\/h3\u003e\n\u003cp\u003eNo, the HT120Z-01 features a strictly oil-free mechanical design. This specific engineering choice is absolutely necessary to ensure the continuous production of medical-grade air purity, completely preventing any aerosolized oil contaminants or lubricants from reaching the patient's respiratory tract. It is heavily engineered to handle a continuous 24-hour duty cycle safely and efficiently without ever requiring routine oil changes or lubrication maintenance from hospital staff.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154805240046,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/Company-Profile-16.jpg?v=1781601316"},{"product_id":"hc80z-dc-medical-oxygenation-pump","title":"HC80Z-11 Medical Oxygenation Pump | 12V, 52W, 24h Continuous Duty","description":"\u003ch2\u003eWhy Choose the HC80Z-11 Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003ePicture a hospital biomedical engineer specifying pumps for a new oxygen concentrator production line; their primary concerns are continuous operation, patient safety, and strict regulatory adherence. In the highly regulated medical device sector, selecting the right internal components can mean the difference between a successful product launch and costly compliance delays. The HC80Z-11 medical oxygenation pump directly addresses these critical engineering needs by providing a highly stable, oil-free pneumatic source designed specifically for continuous 24-hour duty. By integrating this 12V, 52W unit into your manufacturing process, your engineering team ensures that the final respiratory devices will operate quietly, efficiently, and reliably in sensitive clinical environments. The combination of low power consumption and high-reliability continuous operation makes this model an essential asset for modern healthcare equipment.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 12V DC, optimizing compatibility with battery-backed medical systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 52W motor engineered for high efficiency and minimal heat generation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuty Cycle:\u003c\/strong\u003e 24h continuous duty, ensuring uninterrupted performance for critical care applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLubrication System:\u003c\/strong\u003e 100% oil-free mechanism to guarantee medical-grade air purity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAcoustic Performance:\u003c\/strong\u003e Low noise operation specifically designed for bedside patient comfort.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegulatory Compliance:\u003c\/strong\u003e CE MDR 2017\/745 certified for immediate European market access.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuality Management:\u003c\/strong\u003e Manufactured under strict ISO 13485 quality control standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003eHC80Z-11\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eMedical Oxygenation Pump\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Voltage\u003c\/td\u003e\n      \u003ctd\u003e12V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd\u003e52W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDuty Cycle\u003c\/td\u003e\n      \u003ctd\u003e24h Continuous Duty\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLubrication\u003c\/td\u003e\n      \u003ctd\u003eOil-Free\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAir Purity\u003c\/td\u003e\n      \u003ctd\u003eMedical-Grade\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAcoustics\u003c\/td\u003e\n      \u003ctd\u003eLow Noise\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCertifications\u003c\/td\u003e\n      \u003ctd\u003eCE MDR 2017\/745, ISO 13485\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HC80Z-11 is purpose-built for the medical device manufacturing sector, specifically targeting OEMs producing critical care and therapeutic respiratory devices. Its primary application is within oxygen concentrators, where the highly efficient 52W motor provides the precise pneumatic force required to push ambient air through zeolite sieve beds in Pressure Swing Adsorption (PSA) systems. Because it operates on a standard 12V DC power supply, the HC80Z-11 is exceptionally well-suited for portable oxygen concentrators (POCs) and mobile hospital respiratory equipment that rely on battery power or backup power systems during patient transport. The low power draw maximizes battery life, which is a critical specification for mobility-focused medical devices.\u003c\/p\u003e\n\n\u003cp\u003eIn addition to oxygen generation, this medical oxygenation pump is frequently integrated into medical-grade air supply systems used in clinical wards, intensive care units, and specialized surgical environments. The completely oil-free design ensures that no hydrocarbon contaminants, aerosolized oils, or particulate matter enter the air stream. This is a mandatory requirement for any equipment delivering breathable air directly to patients. The continuous 24h duty cycle means the pump can run non-stop without degrading, supporting life-sustaining ventilators, high-flow nasal cannula systems, and continuous positive airway pressure (CPAP) machines without the risk of thermal overload or mechanical failure during critical moments.\u003c\/p\u003e\n\n\u003cp\u003eFurthermore, the low noise characteristics of the HC80Z-11 make it ideal for bedside medical equipment and home healthcare devices. Procurement engineers designing devices for sleep therapy, neonatal incubators, or post-operative recovery rooms consistently specify this pump to maintain a quiet, restful environment for patients. The reduction of mechanical vibration and acoustic output does not compromise its ability to deliver the necessary air volume and pressure, making it a highly balanced solution for advanced medical pneumatics.\u003c\/p\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003eNavigating the complex regulatory landscape of medical device manufacturing requires sourcing components that already meet the strictest international standards. The HC80Z-11 medical oxygenation pump is manufactured in a facility fully certified to ISO 13485, ensuring a comprehensive quality management system dedicated specifically to medical devices. For procurement engineers and OEM buyers, this certification means every single pump coming off the assembly line offers consistent performance, complete component traceability, and strict adherence to documented quality control procedures. This minimizes the risk of batch variations and ensures a reliable supply chain for your production lines.\u003c\/p\u003e\n\n\u003cp\u003eAdditionally, the HC80Z-11 pump complies with the rigorous CE MDR 2017\/745 (Medical Device Regulation), which is mandatory for medical products sold and distributed within the European Economic Area. By sourcing a component that already aligns with CE MDR requirements, technical managers can significantly accelerate their own end-product certification process. This compliance reduces time-to-market, minimizes regulatory friction during audits, and provides documented assurance of the pump's safety, clinical efficacy, and risk management protocols. Whether you are distributing in Europe, North America, or Southeast Asia, these globally recognized certifications provide a strong foundation for your product's regulatory approval.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat does the 24h continuous duty cycle mean for the HC80Z-11 in a clinical setting?\u003c\/h3\u003e\n\u003cp\u003eThe 24h continuous duty cycle indicates that the\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154806452462,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/Company-Profile-13.jpg?v=1781601339"},{"product_id":"hc580dc-medical-oxygenation-pump","title":"HC580DC Medical Oxygenation Pump | 650W, 140L\/min, CE MDR","description":"\u003ch2\u003eWhy Choose the HC580DC Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003eConsider a respiratory therapy device OEM needing pumps with 20,000h MTBF for critical care applications. When patient outcomes depend on continuous, uninterrupted airflow, engineers require components that guarantee absolute reliability without introducing oil or particulate contamination. The HC580DC medical oxygenation pump fulfills this critical requirement by combining a continuous 24-hour duty cycle with medical-grade air purity, ensuring life-supporting equipment operates predictably across its entire service life.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Volume Output:\u003c\/strong\u003e Delivers a consistent air flow rate of ≥140L\/min at a rated pressure of 200Kpa.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Power Consumption:\u003c\/strong\u003e Operates at ≤650W at rated pressure, maximizing energy efficiency for continuous-use medical systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAcoustic Control:\u003c\/strong\u003e Maintains a low noise profile of ≤66dB(A), essential for patient comfort in clinical and home care environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Lifespan:\u003c\/strong\u003e Engineered for a 20,000h MTBF and capable of a continuous 24h duty cycle for round-the-clock operation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStrict Compliance:\u003c\/strong\u003e Fully certified to CE MDR 2017\/745 and ISO 13485 standards for immediate integration into regulated medical devices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile DC Power Integration:\u003c\/strong\u003e Available in 12V, 24V, and 48V configurations to match various OEM electrical architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Numbers\u003c\/td\u003e\n      \u003ctd\u003eHC580C1-140\/2 (12V) \/ HC580D1-140\/2 (24V) \/ HC580E1-140\/2 (48V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHead Configuration\u003c\/td\u003e\n      \u003ctd\u003ePressure parallel flow\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVoltage Options\u003c\/td\u003e\n      \u003ctd\u003e12V \/ 24V \/ 48V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNoise Level\u003c\/td\u003e\n      \u003ctd\u003e≤66dB(A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower at Rated Pressure\u003c\/td\u003e\n      \u003ctd\u003e≤650W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAir Flow Rate\u003c\/td\u003e\n      \u003ctd\u003e≥140L\/min @ 200Kpa\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpeed at Rated Pressure\u003c\/td\u003e\n      \u003ctd\u003e1700rpm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimension\u003c\/td\u003e\n      \u003ctd\u003e276 * 133 * 202 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Size\u003c\/td\u003e\n      \u003ctd\u003e223 * 89 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e7.3 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSupported Equipment\u003c\/td\u003e\n      \u003ctd\u003eFor dental chairs (5-6 units)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCompressor Type\u003c\/td\u003e\n      \u003ctd\u003eDC Oil Free Air Compressor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HC580DC medical oxygenation pump is engineered primarily for manufacturers of high-capacity oxygen concentrators and hospital respiratory equipment. In oxygen generation systems, the pump forces ambient air through zeolite sieve beds at 200Kpa to separate nitrogen from oxygen. The high flow rate of ≥140L\/min allows OEMs to design multi-patient oxygen delivery systems or high-output industrial medical-grade air supply units. Because the compressor is completely oil-free, it prevents hydrocarbon contamination, ensuring the final oxygen output meets strict medical purity standards.\u003c\/p\u003e\n\u003cp\u003eBeyond oxygen generation, this DC oil-free air compressor serves as a highly effective central vacuum or pressure source for dental clinics. The specifications explicitly support powering 5 to 6 dental chairs simultaneously. The ≤66dB(A) noise level ensures that it can be installed within clinical environments without causing auditory fatigue for dental practitioners or anxiety for patients. The compact 276x133x202 mm dimensions and 223x89 mm installation footprint allow it to be integrated into standard utility rooms or directly inside large-scale medical device housings.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the availability of 12V, 24V, and 48V DC models makes the HC580DC highly adaptable for portable or battery-backed hospital respiratory equipment. During power outages or patient transport, medical-grade air supply systems must rely on DC battery power. The efficient ≤650W power draw at 1700rpm operating speed helps preserve battery life while maintaining the critical 200Kpa pressure required for ventilators and continuous positive airway pressure systems.\u003c\/p\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003eFor B2B procurement engineers and compliance officers, the regulatory standing of a medical component is just as critical as its physical specifications. The HC580DC is manufactured in an ISO 13485-certified facility, which guarantees that HCEM Pump adheres to a comprehensive quality management system specific to the design and manufacture of medical devices. This certification simplifies supplier audits for OEMs and ensures complete traceability, risk management, and consistent manufacturing quality across all production batches.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the pump complies with the CE Medical Device Regulation (MDR) 2017\/745. This certification is mandatory for any medical equipment sold within the European Economic Area (EEA). By sourcing a pump that already meets CE MDR 2017\/745 standards, respiratory equipment manufacturers can significantly reduce the time, cost, and complexity of certifying their final assembled products for the European market. It provides documented proof of the pump's safety, clinical efficacy, and adherence to stringent European health and safety directives.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat are the installation and spatial requirements for the HC580DC pump?\u003c\/h3\u003e\n\u003cp\u003eThe HC580DC features a compact physical dimension of 276 mm in length, 133 mm in width, and 202 mm in height. For mounting, the installation size requires a footprint of 223 mm by 89 mm. Weighing 7.3 kg, the unit is stable enough for fixed installations in hospital utility rooms while remaining light enough for integration into mobile medical carts. The pressure parallel flow head configuration simplifies pneumatic plumbing during the assembly process.\u003c\/p\u003e\n\n\u003ch3\u003eIs the HC580DC suitable for centralized dental air systems?\u003c\/h3\u003e\n\u003cp\u003eYes, the HC580DC is specifically rated to support 5 to 6 dental chairs simultaneously. Its output of ≥140L\/min at 200Kpa ensures that multiple pneumatic dental tools can operate concurrently without experiencing a drop in air pressure. Furthermore, its oil-free design ensures that the air supplied to the dental handpieces remains clean, protecting both patient health and the internal mechanisms of the dental equipment.\u003c\/p\u003e\n\n\u003ch3\u003eHow do the different model numbers correspond to electrical requirements?\u003c\/h3\u003e\n\u003cp\u003eThe HC580DC series is available in three distinct voltage configurations to match your system's power architecture. The HC580C1-140\/2 operates on a 12V DC supply, the HC580D1-140\/2 is designed for 24V DC systems, and the HC580E1-140\/2 requires a 48V DC input. Regardless of the voltage selected, all three models maintain the same performance metrics: ≤650W power consumption, 1700rpm speed, and ≥140L\/min flow rate at 200Kpa.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154857275630,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/E4_B8_BB_E5_9B_BE-40.jpg?v=1781602278"},{"product_id":"hc280dc-medical-oxygenation-pump","title":"HC280DC Medical Oxygenation Pump | 340W, 70L\/min, 24h Duty Cycle","description":"\u003ch2\u003eWhy Choose the HC280DC Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003eWhen a hospital biomedical engineer is specifying pumps for a new oxygen concentrator production line, finding a balance between continuous operation and absolute air purity is the primary challenge. The HC280DC medical oxygenation pump is manufactured specifically to solve this problem, providing OEM designers with a highly dependable, oil-free pneumatic source. By integrating this unit, medical device manufacturers ensure their hospital respiratory equipment operates continuously without risking oil contamination in the patient air supply, reducing maintenance intervals and improving overall patient safety.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower Consumption: 340W motor designed for high electrical efficiency in medical devices.\u003c\/li\u003e\n  \u003cli\u003eFlow Rate: Consistent 70L\/min output to support high-capacity oxygen concentrators.\u003c\/li\u003e\n  \u003cli\u003eDuty Cycle: 24h continuous operation capability for life-support and constant-care applications.\u003c\/li\u003e\n  \u003cli\u003eLubrication: 100% oil-free operation ensuring medical-grade air purity without filter degradation.\u003c\/li\u003e\n  \u003cli\u003eAcoustics: Low noise profile engineered specifically for quiet hospital and clinical environments.\u003c\/li\u003e\n  \u003cli\u003eCertifications: Fully compliant with CE MDR 2017\/745 for immediate European medical market access.\u003c\/li\u003e\n  \u003cli\u003eQuality Standards: Manufactured in an ISO 13485 certified facility ensuring strict batch consistency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003eHC280DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eMedical Oxygenation Pump\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower\u003c\/td\u003e\n      \u003ctd\u003e340W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlow Rate\u003c\/td\u003e\n      \u003ctd\u003e70L\/min\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDuty Cycle\u003c\/td\u003e\n      \u003ctd\u003e24h Continuous\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLubrication Type\u003c\/td\u003e\n      \u003ctd\u003eOil-free\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNoise Level\u003c\/td\u003e\n      \u003ctd\u003eLow noise\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAir Quality\u003c\/td\u003e\n      \u003ctd\u003eMedical-grade air purity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRegulatory Compliance\u003c\/td\u003e\n      \u003ctd\u003eCE MDR 2017\/745\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eQuality Management\u003c\/td\u003e\n      \u003ctd\u003eISO 13485\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HC280DC medical oxygenation pump is engineered specifically for integration into high-capacity oxygen concentrators. In these systems, the pump draws in ambient room air and pushes it under precise pressure through zeolite sieve beds to separate nitrogen, leaving highly concentrated oxygen for patient use. The consistent 70L\/min flow rate powered by the highly efficient 340W motor provides the exact pneumatic force required for multi-patient or high-flow concentrator models commonly utilized in clinical wards and intensive care units. Because the pump operates on a 24-hour continuous duty cycle, it meets the strict operational demands of life-critical respiratory systems that simply cannot afford mechanical downtime or fluctuations in air delivery.\u003c\/p\u003e\n\u003cp\u003eBeyond primary oxygen generation, this medical oxygenation pump is a critical internal component for advanced hospital respiratory equipment, including mechanical ventilators and continuous positive airway pressure (CPAP) or bilevel positive airway pressure (BiPAP) machines that require an internal, reliable medical-grade air supply. The completely oil-free design ensures that no aerosolized lubricants, hydrocarbons, or particulate contaminants enter the patient's airway, which is a strict safety requirement for all pulmonary medical devices. Furthermore, the low noise output of the HC280DC allows these machines to be placed directly in patient rooms, neonatal intensive care units, and surgical recovery wards without causing auditory distress to resting patients or interfering with the communication of clinical staff.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the HC280DC serves as a highly dependable central component for localized medical-grade air supply systems in smaller outpatient clinics, dental offices, or mobile medical transport units. Dental clinics, outpatient surgical centers, and emergency transport vehicles utilize this exact pump model to drive pneumatic surgical tools, operate suction devices, and provide clean breathing air. Procurement engineers and technical directors in the medical OEM sector rely on this specific model to standardize their pneumatic internal assemblies across multiple product lines, effectively reducing inventory complexity and maintenance training while maintaining strict adherence to international medical device regulations.\u003c\/p\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003eRegulatory compliance is the most critical factor for procurement managers sourcing components for medical devices. The HC280DC medical oxygenation pump holds CE MDR 2017\/745 certification, which is the current European Union Medical Device Regulation. This certification ensures that the pump meets strict safety, performance, and clinical evaluation standards required for legal distribution and integration within the European Economic Area. For OEM buyers, utilizing an MDR-certified pump significantly accelerates the final approval process for their completed oxygen concentrators and respiratory equipment, mitigating regulatory risks and reducing time-to-market for new medical technologies.\u003c\/p\u003e\n\u003cp\u003eIn addition to European product standards, HCEM Pump manufactures the HC280DC under a strict ISO 13485 quality management system. ISO 13485 is the internationally recognized standard specific to the medical device manufacturing industry, demonstrating that the production facility maintains rigorous traceability, risk management, and quality control processes. This standard provides procurement engineers in North America, Europe, and Southeast Asia with documented assurance that every pump delivered will perform identically to the qualified prototype, ensuring consistent medical-grade air purity and reliable 24-hour continuous operation across all commercial production batches.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow does the 24h continuous duty cycle of the HC280DC affect its lifespan?\u003c\/h3\u003e\n\u003cp\u003eThe HC280DC is specifically manufactured for a 24h continuous duty cycle, meaning it can operate non-stop without requiring cooldown periods. This is achieved through the highly efficient 340W motor and specialized heat dissipation design. Because it is built from the ground up for continuous medical use, running it 24 hours a day is its intended operational state and will not prematurely degrade the internal oil-free components, provided it is operated within standard clinical environmental conditions.\u003c\/p\u003e\n\u003ch3\u003eIs the HC280DC suitable for integration into portable oxygen concentrators?\u003c\/h3\u003e\n\u003cp\u003eWhile the HC280DC provides an excellent medical-grade air supply and a substantial flow rate of 70L\/min, its 340W power requirement and output capacity make it more suitable for stationary, high-capacity hospital respiratory equipment and centralized clinical oxygen concentrators rather than small, battery-operated portable units. It is the ideal choice for stationary OEM medical devices where continuous, high-volume pneumatic performance is the primary engineering requirement.\u003c\/p\u003e\n\u003ch3\u003eCan HCEM Pump provide documentation for the CE MDR 2017\/745 and ISO 13485 certifications?\u003c\/h3\u003e\n\u003cp\u003eYes. HCEM Pump maintains full traceability and compliance documentation for the HC280DC medical oxygenation pump. OEM buyers and technical managers can request the complete certification packet, including the ISO 13485 facility registration and the CE MDR 2017\/745 compliance declarations, to support their own medical device regulatory submissions, technical files, and quality assurance audits.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154858258670,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/23f8977fabe577fc7854fa4fd9d18f2_f86c415b-0193-403a-b64e-a5ccbe53f126.webp?v=1781602297"},{"product_id":"hc210dc-medical-oxygenation-pump","title":"HC210DC Medical Oxygenation Pump | 230W, ≥50L\/min, CE MDR","description":"\u003ch2\u003eWhy Choose the HC210DC Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003eWhen a home care equipment manufacturer needing CE MDR-compliant pumps for portable oxygen devices evaluates pneumatic components, their primary focus is on continuous reliability and patient safety. The HC210DC medical oxygenation pump provides the exact specifications required to meet these clinical demands, offering a dependable, oil-free pneumatic core for life-supporting respiratory devices. By integrating this pump, OEM buyers can ensure a consistent medical-grade air supply while streamlining their own compliance and manufacturing processes.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Flow Performance:\u003c\/strong\u003e Delivers a consistent air flow rate of ≥50L\/min at a rated pressure of 140 Kpa, ensuring adequate pneumatic power for high-capacity oxygen concentrators.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Power Consumption:\u003c\/strong\u003e Operates at 230W at rated pressure, providing efficient energy utilization across 12V, 24V, and 48V DC systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAcoustic Control:\u003c\/strong\u003e Engineered for patient comfort with a noise output of ≤62dB(A), making it highly suitable for bedside hospital respiratory equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuous Operation:\u003c\/strong\u003e Designed for a continuous 24h duty cycle at 1700rpm, guaranteeing uninterrupted medical-grade air supply for critical care applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Integration:\u003c\/strong\u003e Features a space-saving footprint with dimensions of 177x98x150 mm and a standard installation size of 114x70mm, weighing just 3.1 kg.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStrict Medical Compliance:\u003c\/strong\u003e Manufactured under ISO 13485 quality management and fully compliant with CE MDR 2017\/745 regulations for medical devices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClean Air Delivery:\u003c\/strong\u003e Utilizes a 100% oil-free compression mechanism, preventing hydrocarbon contamination in the patient air path.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel Numbers\u003c\/td\u003e\n\u003ctd\u003eHC210C-50\/1.4 (12V), HC210D-50\/1.4 (24V), HC210E-50\/1.4 (48V)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHead Configuration\u003c\/td\u003e\n\u003ctd\u003ePressure parallel flow\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e12V \/ 24V \/ 48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003e≤62dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePower at Rated Pressure\u003c\/td\u003e\n\u003ctd\u003e230W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAir Flow Rate\u003c\/td\u003e\n\u003ctd\u003e≥50L\/min @ 140 Kpa\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSpeed at Rated Pressure\u003c\/td\u003e\n\u003ctd\u003e1700rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e177 x 98 x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInstallation Size\u003c\/td\u003e\n\u003ctd\u003e114 x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e3.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HC210DC medical oxygenation pump is specifically engineered to serve as the primary pneumatic engine for high-capacity oxygen concentrators. In these devices, the pump forces ambient air through dense zeolite sieve beds to separate nitrogen from oxygen. The requirement for a continuous 24h duty cycle is critical in this application, as patients relying on oxygen therapy require an uninterrupted flow. With an output of ≥50L\/min at a rated pressure of\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154859110638,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/E4_B8_BB_E5_9B_BE-30.jpg?v=1781602320"},{"product_id":"hc100dc-medical-oxygenation-pump","title":"HC100DC Medical Oxygenation Pump | 150W, 36L\/min, Oil-Free, CE","description":"\u003ch2\u003eWhy Choose the HC100DC Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003eWhen a hospital biomedical engineer is specifying pumps for a new oxygen concentrator production line, component failure is simply not an option. The HC100DC medical oxygenation pump is engineered specifically to provide the continuous, contaminant-free airflow required in critical care environments and life-supporting medical devices. By utilizing an advanced oil-free pneumatic design and a continuous 24-hour duty cycle, this unit ensures that medical-grade air supply systems operate reliably without the risk of lubricant contamination or unexpected thermal overload. OEM buyers require predictable performance, and this pump delivers exact pneumatic consistency day in and day out. Furthermore, the low noise characteristics mean it can be safely deployed in patient-facing clinical environments without causing auditory distress, making it an ideal core component for modern hospital respiratory equipment.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 150W motor optimized for continuous, energy-efficient operation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 36L\/min capacity ensuring steady and consistent air delivery\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLubrication:\u003c\/strong\u003e 100% Oil-Free design guaranteeing medical-grade air purity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuty Cycle:\u003c\/strong\u003e Continuous 24h operation capability for uninterrupted patient care\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAcoustics:\u003c\/strong\u003e Low noise output engineered specifically for quiet clinical and hospital wards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e Fully compliant with European CE MDR 2017\/745 and global ISO 13485 standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel Number\u003c\/td\u003e\n      \u003ctd\u003eHC100DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePump Type\u003c\/td\u003e\n      \u003ctd\u003eMedical Oxygenation Pump\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower\u003c\/td\u003e\n      \u003ctd\u003e150W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlow Rate\u003c\/td\u003e\n      \u003ctd\u003e36L\/min\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLubrication\u003c\/td\u003e\n      \u003ctd\u003eOil-Free\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDuty Cycle\u003c\/td\u003e\n      \u003ctd\u003eContinuous 24h\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAir Purity\u003c\/td\u003e\n      \u003ctd\u003eMedical-grade\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNoise Level\u003c\/td\u003e\n      \u003ctd\u003eLow noise\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCertifications\u003c\/td\u003e\n      \u003ctd\u003eCE MDR 2017\/745, ISO 13485\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HC100DC is meticulously designed to serve as the core pneumatic engine for high-demand oxygen concentrators. In these complex systems, ambient air is drawn in and forcefully passed through zeolite molecular sieves to separate nitrogen from oxygen. The 36L\/min flow rate and 150W power specification provide the exact pneumatic force required to push air through these sieve beds efficiently, ensuring a steady output of highly concentrated oxygen for patients suffering from respiratory distress. The 100% oil-free mechanism is highly critical in this application, as any introduction of hydrocarbons into an oxygen-rich environment poses severe fire safety risks and directly degrades the patient's breathable air quality.\u003c\/p\u003e\n\u003cp\u003eBeyond standard oxygen generation, this medical oxygenation pump is heavily utilized in broader hospital respiratory equipment. Advanced ventilators, Continuous Positive Airway Pressure (CPAP) machines, and high-flow nasal cannula systems rely on consistent, low-noise air delivery to function correctly. These machines must operate without disturbing the patient's recovery environment or triggering false alarms due to pressure drops. The continuous 24h duty cycle of the HC100DC ensures that these life-supporting devices can operate around the clock in intensive care units, neonatal wards, and specialized respiratory clinics without requiring frequent pump cooldown periods or emergency maintenance interventions.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the HC100DC supports centralized medical-grade air supply systems in smaller regional clinics, dental surgical suites, or mobile medical units. Procurement engineers and technical managers integrating this pump into OEM medical devices benefit from its predictable flow dynamics and strict adherence to clinical safety standards. Whether deployed in Southeast Asian mobile triage clinics, European intensive care units, or North American home-care respiratory devices, the pump meets the strict operational parameters demanded by the global healthcare manufacturing industry.\u003c\/p\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003eRegulatory compliance is a primary concern for OEM buyers, technical managers, and procurement engineers operating in the highly regulated medical device sector. The HC100DC medical oxygenation pump is manufactured in strict accordance with ISO 13485 standards. This international certification demonstrates that HCEM Pump maintains a comprehensive quality management system specifically tailored for the design, testing, and manufacture of medical devices. For B2B buyers, this translates to consistent batch-to-batch manufacturing quality, rigorous traceability of all internal components, and a structured approach to risk management throughout the entire production lifecycle. It provides assurance that the supply chain is secure and audited.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the HC100DC complies with the European Union's updated Medical Device Regulation (CE MDR 2017\/745). This certification is mandatory for medical components and finished devices entering the European market, ensuring the pump meets the most stringent safety, clinical performance, and environmental standards currently enforced. By sourcing a pump that already carries CE MDR 2017\/745 compliance, technical managers can significantly reduce the regulatory friction, documentation burden, and testing timelines required when registering their final medical assemblies—such as oxygen concentrators or hospital respiratory equipment—for commercial sale in Europe and other international regions that recognize CE marking.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow does the continuous 24h duty cycle affect the HC100DC's maintenance schedule?\u003c\/h3\u003e\n\u003cp\u003eThe HC100DC is engineered with a specialized 150W motor and an oil-free mechanism specifically designed to handle continuous 24-hour operation without thermal degradation or mechanical fatigue. Because it does not rely on lubricating oil, there is no need for routine oil changes, oil level monitoring, or specialized filter replacements associated with fluid-lubricated pumps. Maintenance is generally limited to periodic visual inspections of the intake filters and the scheduled replacement of standard wear components like piston rings or diaphragms. This low-maintenance profile allows hospital respiratory equipment to remain in active clinical service longer between scheduled maintenance intervals, reducing total cost of ownership.\u003c\/p\u003e\n\n\u003ch3\u003eIs the HC100DC suitable for integration into portable oxygen concentrators?\u003c\/h3\u003e\n\u003cp\u003eThe HC100DC provides a substantial flow rate of 36L\/min and requires 150W of electrical power. While these specifications make it highly effective for stationary bedside oxygen concentrators, high-capacity hospital units, and home care settings, procurement engineers must carefully evaluate the 150W power draw against the battery capacity of portable, wearable units. It is primarily specified for equipment where stable, continuous medical-grade air supply is prioritized over ultra-lightweight, battery-operated portability. For stationary OEM applications, it provides the exact pneumatic stability required.\u003c\/p\u003e\n\n\u003ch3\u003eDoes the oil-free design guarantee medical-grade air purity?\u003c\/h3\u003e\n\u003cp\u003eYes, the oil-free design of the HC100DC ensures that absolutely no lubricating fluids, aerosols, or hydrocarbon vapors are introduced into the air stream during the compression process. This is a fundamental, non-negotiable requirement for achieving medical-grade air purity, making the pump entirely safe for direct integration into hospital respiratory equipment and oxygen concentrators where vulnerable patients directly inhale the processed air. The strict adherence to ISO 13485 manufacturing standards further ensures that the factory assembly environment prevents any cross-contamination before the pump is shipped to the OEM buyer.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154859897070,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/E4_B8_BB_E5_9B_BE-29.jpg?v=1781602340"},{"product_id":"hc80dc-medical-oxygenation-pump","title":"HC80DC Medical Oxygenation Pump | 90W, 17L\/min, 24h Duty","description":"_DESCRIPTION: When a hospital biomedical engineer is specifying pumps for a new oxygen concentrator production line, reliability is the primary concern. The HC80DC medical oxygenation pump delivers consistent performance for critical care applications. Operating on 90W of power, this oil-free unit provides a steady flow rate of 17L\/min with a continuous 24h duty cycle. Designed for low noise operation, it ensures patient comfort while maintaining medical-grade air purity. Compliant with CE MDR 2017\/745 and ISO 13485, it meets strict regulatory requirements for medical devices. Ideal for integration into oxygen concentrators, hospital respiratory equipment, and medical-grade air supply systems. Manufacturers benefit from a dependable component that reduces maintenance costs and ensures equipment longevity. For B2B buyers seeking compliant, efficient pneumatics, the HC80DC offers consistent integration and long-term operational stability.\n\nLONG_DESCRIPTION:\n\n\u003ch2\u003eWhy Choose the HC80DC Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003eWhen a hospital biomedical engineer is specifying pumps for a new oxygen concentrator production line, the focus immediately shifts to consistent performance, patient safety, and rigorous regulatory compliance. The HC80DC medical oxygenation pump addresses these critical requirements by providing dependable, oil-free pneumatic power designed specifically for demanding healthcare environments. By eliminating the risk of oil contamination, this unit ensures that the generated airflow meets the stringent purity requirements necessary for direct patient respiratory support.\u003c\/p\u003e\n\u003cp\u003eEfficiency is another major factor in medical device design. Operating at 90W, this pump balances energy consumption with a steady output of 17L\/min. This specific power-to-flow ratio allows designers to build compact oxygen concentrators that do not draw excessive current from hospital circuits or home electrical systems. Additionally, the low noise output helps maintain a healing environment for patients, avoiding the mechanical hum that often accompanies high-capacity compressors. By standardizing on this model, manufacturers gain a reliable, quiet, and efficient pneumatic core for their medical assemblies.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 90W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 17L\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuty Cycle:\u003c\/strong\u003e 24h Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLubrication:\u003c\/strong\u003e Oil-free\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcoustics:\u003c\/strong\u003e Low noise\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Quality:\u003c\/strong\u003e Medical-grade air purity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE MDR 2017\/745, ISO 13485\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHC80DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMedical Oxygenation Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e90W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate\u003c\/td\u003e\n\u003ctd\u003e17L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e24h Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLubrication Method\u003c\/td\u003e\n\u003ctd\u003eOil-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic Profile\u003c\/td\u003e\n\u003ctd\u003eLow noise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Purity\u003c\/td\u003e\n\u003ctd\u003eMedical-grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality Systems\u003c\/td\u003e\n\u003ctd\u003eISO 13485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eCE MDR 2017\/745\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HC80DC medical oxygenation pump is engineered specifically for integration into critical healthcare devices where consistent airflow is a fundamental requirement. Its primary application is within oxygen concentrators. In these devices, the pump draws in ambient air and pushes it through sieve beds containing zeolite, which absorbs nitrogen and allows purified oxygen to pass through to the patient. The 17L\/min flow rate and 90W power profile make it highly suitable for stationary, high-capacity oxygen concentrators used in clinical settings or home care environments where patients require continuous, reliable oxygen therapy.\u003c\/p\u003e\n\u003cp\u003eBeyond oxygen generation, this pump serves as a vital component in hospital respiratory equipment, including continuous positive airway pressure (CPAP) machines, bilevel positive airway pressure (BiPAP) devices, and medical ventilators. The continuous 24h duty cycle ensures that these life-supporting machines can operate day and night without the risk of thermal overload or mechanical failure. Furthermore, the oil-free design guarantees that the air delivered to the patient's lungs remains completely free of particulate matter or hydrocarbon contamination, maintaining strict medical-grade air supply standards. The absence of oil means no fine mist is ever aerosolized into the breathing circuit.\u003c\/p\u003e\n\u003cp\u003eMedical facilities also utilize the HC80DC in centralized medical-grade air supply systems and bedside aspiration units. In these scenarios, the low noise operation becomes highly beneficial, preventing auditory fatigue for healthcare workers and preserving a quiet, restful environment for patient recovery. Equipment manufacturers rely on the precise 17L\/min flow delivery to calibrate their respiratory therapy algorithms accurately, ensuring that the end-user receives the exact prescribed dosage of oxygen or pressurized air. The combination of its physical dimensions, thermal management, and output consistency makes it an ideal fit for biomedical engineers looking to source a dependable pneumatic engine for next-generation respiratory medical devices. The steady output helps in maintaining exact pressure gradients required for sensitive pediatric and adult pulmonary treatments.\u003c\/p\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003eNavigating the regulatory landscape of medical device manufacturing requires components that meet strict international standards. The HC80DC is manufactured in a facility compliant with ISO 13485. This certification demonstrates a comprehensive quality management system specifically tailored to the design and manufacture of medical devices. For B2B buyers and original equipment manufacturers (OEMs), sourcing an ISO 13485-certified pump means the production processes, traceability, and risk management protocols have been rigorously audited. This standard assures manufacturers that every unit off the assembly line maintains the exact same performance characteristics, reducing the risk of end-product failure and simplifying the OEM's own quality assurance audits.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the pump complies with the European Union's Medical Device Regulation (CE MDR 2017\/745). This regulation is one of the most stringent medical device frameworks globally, focusing heavily on clinical safety, post-market surveillance, and verifiable performance data. Compliance with CE MDR 2017\/745 allows equipment manufacturers to legally place their final medical devices on the market within the European Economic Area (EEA). By utilizing a pump that already meets these rigorous standards, biomedical engineers and compliance officers can significantly reduce the time and cost associated with certifying their final oxygen concentrators or respiratory equipment. It provides a documented pathway of safety and efficacy, ensuring that the component will not compromise the overall regulatory approval of the final medical assembly. This level of certification guarantees that the materials used in the pump's construction are biocompatible and safe for gas pathway applications.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat does the 24h continuous duty cycle mean for equipment maintenance?\u003c\/h3\u003e\n\u003cp\u003eThe 24h continuous duty cycle indicates that the HC80DC medical oxygenation pump is thermally and mechanically designed to operate non-stop, 24 hours a day, without requiring rest periods to prevent overheating. Operating at 90W, the motor effectively dissipates heat. For hospital respiratory equipment and oxygen concentrators, this means the pump will not be the limiting factor in the device's operational availability. Maintenance intervals are extended, and downtime is minimized, which is critical for life-support or continuous therapy applications.\u003c\/p\u003e\n\n\u003ch3\u003eIs the HC80DC suitable for hospital respiratory equipment requiring direct patient air delivery?\u003c\/h3\u003e\n\u003cp\u003eYes, the HC80DC is highly suitable for hospital respiratory equipment. Because it features an entirely oil-free mechanism, it introduces no lubricating fluids or hydrocarbon vapors into the air path. This design guarantees medical-grade air purity, making it safe for direct patient respiratory applications, including ventilators and continuous positive airway pressure systems. The low noise characteristic also ensures it meets the acoustic limits required for bedside medical equipment, maintaining a peaceful environment for clinical recovery.\u003c\/p\u003e\n\n\u003ch3\u003eCan this pump be used in automated medical-grade air supply networks?\u003c\/h3\u003e\n\u003cp\u003eYes, the unit provides a consistent flow rate of 17L\/min, which can be integrated into smaller, localized medical-grade air supply networks or automated blending systems within clinical environments. The adherence to CE MDR 2017\/745 and ISO 13485 ensures that it meets the necessary safety and reliability metrics required for infrastructural medical air generation. B2B buyers can integrate this pump into their custom manifolds knowing the pneumatic output will remain stable over its extended service life.\u003c\/p\u003e\n\n\u003ch3\u003eHow does the ISO 13485 certification impact B2B procurement?\u003c\/h3\u003e\n\u003cp\u003eFor procurement teams and medical device manufacturers, purchasing an ISO 13485 certified component directly impacts the supply chain's reliability and risk profile. It guarantees that the HC80DC is produced under strict quality controls, with full traceability of materials and manufacturing steps. This reduces the burden of incoming quality inspections and significantly lowers the risk of batch defects, ensuring smooth production schedules for oxygen concentrators and other critical medical devices.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154861273326,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/Company-Profile-15.jpg?v=1781602366"},{"product_id":"hc680-medical-oxygenation-pump","title":"HC680 Medical Oxygenation Pump | 130L\/min, 200Kpa, Oil-Free","description":"\u003cp\u003eThe HC680 medical oxygenation pump delivers 100L\/min oil-free airflow for oxygen concentrators, respiratory equipment, and sterile air systems. As a medical oxygen pump manufacturer, HC Pump supports OEM customization, wholesale supply, and compliance-focused production.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154862780654,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/E5_BE_AE_E4_BF_A1_E5_9B_BE_E7_89_87_202506252109271.jpg?v=1781602393"},{"product_id":"hc580-medical-oxygenation-pump","title":"HC580 Medical Oxygenation Pump | ≤580W, Oilless, ≤62dB(A), CE MDR","description":"\u003cp\u003eThe HC580 medical oxygenation pump delivers 85L\/min oil-free airflow with low noise for reliable oxygen concentrator and hospital equipment integration. As a medical air pump manufacturer, HC Pump supports OEM customization and wholesale supply for global B2B buyers.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154864124142,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/E4_B8_BB_E5_9B_BE-28.jpg?v=1781602419"},{"product_id":"hc280-medical-oxygenation-pump","title":"HC280 Medical Oxygenation Pump | 350W, 70L\/min, Oil-Free","description":"\u003ch2\u003eWhy Choose the HC280 Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003eWhen a hospital biomedical engineer is specifying pumps for a new oxygen concentrator production line, the focus is immediately on continuous reliability and absolute contamination control. The HC280 medical oxygenation pump is manufactured to meet these exact clinical demands, providing a dependable pneumatic core for life-supporting devices. By integrating an advanced oil-free compression mechanism, it ensures the delivery of medical-grade air without the risk of lubricant particulate contamination. In high-stakes healthcare environments, equipment failure is not an option. The engineering behind this model focuses on thermal management and mechanical stability, allowing the 350W motor to operate efficiently without excessive heat generation. This careful balance of power and efficiency ensures that the 70L\/min flow rate remains consistent, even during prolonged periods of high demand in intensive care units or localized clinical settings.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 350W optimized for continuous clinical use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 70L\/min consistent pneumatic output\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuty Cycle:\u003c\/strong\u003e Continuous 24h operation for life-support systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLubrication:\u003c\/strong\u003e 100% Oil-free mechanism preventing contamination\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNoise Level:\u003c\/strong\u003e Low noise design suitable for bedside patient care\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e Fully compliant with CE MDR 2017\/745 and ISO 13485\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir Purity:\u003c\/strong\u003e Delivers strictly medical-grade air supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eHC280\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eMedical Oxygenation Pump\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower\u003c\/td\u003e\n      \u003ctd\u003e350W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlow Rate\u003c\/td\u003e\n      \u003ctd\u003e70L\/min\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDuty Cycle\u003c\/td\u003e\n      \u003ctd\u003eContinuous 24h\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLubrication Type\u003c\/td\u003e\n      \u003ctd\u003eOil-free\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAir Quality\u003c\/td\u003e\n      \u003ctd\u003eMedical-grade air purity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAcoustics\u003c\/td\u003e\n      \u003ctd\u003eLow noise\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCertifications\u003c\/td\u003e\n      \u003ctd\u003eCE MDR 2017\/745, ISO 13485\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HC280 medical oxygenation pump is specifically designed for integration into high-capacity oxygen concentrators. In these systems, the 70L\/min flow rate and 350W power profile provide the exact pneumatic force required to efficiently drive the pressure swing adsorption (PSA) process. Because the pump operates on a strictly oil-free basis, it prevents any hydrocarbon contamination from reaching the sensitive zeolite sieve beds. This feature is highly critical for maintaining the efficiency and extending the operational lifespan of the nitrogen-adsorption process, ultimately reducing maintenance costs for healthcare providers and equipment operators.\u003c\/p\u003e\n\u003cp\u003eBeyond oxygen concentrators, this unit serves as a vital internal component in various types of hospital respiratory equipment. This includes high-flow nasal cannula (HFNC) devices, specialized ventilators, and localized medical-grade air supply systems. The continuous 24h duty cycle capability ensures that ventilators and centralized ward air systems can function without interruption during critical patient care scenarios. Furthermore, the low noise output of the HC280 is particularly important for bedside equipment. By minimizing operational decibels, it prevents auditory fatigue for both recovering patients and healthcare professionals working long shifts in intensive care units and recovery wards.\u003c\/p\u003e\n\u003cp\u003eOEM buyers, procurement engineers, and technical managers in Europe, North America, and Southeast Asia utilize the HC280 to build compliant, reliable medical devices. Whether outfitting a localized clinic's respiratory therapy room, designing dental surgical air systems, or manufacturing a fleet of portable clinical oxygen generators, procurement professionals rely on this pump's stable flow dynamics. The strict adherence to medical-grade air purity ensures that end-users receive safe, therapeutic respiratory support precisely when they need it most.\u003c\/p\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003eRegulatory compliance is a non-negotiable requirement for medical device procurement and manufacturing. The HC280 medical oxygenation pump is fully certified under the stringent CE MDR 2017\/745 regulations. This ensures it meets the comprehensive safety, clinical evaluation, and performance requirements mandated for medical devices entering or operating within the European Union. By sourcing a component that already holds this rigorous certification, OEM manufacturers gain the necessary technical documentation to streamline their own final product approvals, significantly reducing administrative burdens and accelerating time-to-market for new respiratory equipment.\u003c\/p\u003e\n\u003cp\u003eFurthermore, HCEM Pump manufactures the HC280 in strict accordance with ISO 13485 quality management standards specific to the medical device industry. This standard guarantees complete component traceability, thorough risk management protocols, and consistent manufacturing quality across every single production batch. For technical managers and procurement engineers operating in North America, Southeast Asia, and other global markets, this ISO certification serves as an internationally recognized indicator of absolute quality assurance. It minimizes supply chain risks, standardizes procurement audits, and ensures that every delivered unit performs exactly to its stated 350W and 70L\/min specifications without deviation.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the exact duty cycle of the HC280 medical oxygenation pump, and how does it affect maintenance?\u003c\/h3\u003e\n\u003cp\u003eThe HC280 is engineered for a continuous 24h duty cycle. This constant operation capability makes it highly suitable for life-supporting hospital respiratory equipment and oxygen concentrators that must run without interruption for days or weeks at a time. Because it utilizes a durable oil-free mechanism, it eliminates the need for regular oil changes or lubrication checks, thereby extending the standard maintenance intervals and lowering the total cost of ownership for healthcare facilities.\u003c\/p\u003e\n\n\u003ch3\u003eIs the HC280 suitable for direct integration into hospital respiratory equipment?\u003c\/h3\u003e\n\u003cp\u003eYes, the HC280 is specifically engineered to function as the core pneumatic driver for hospital respiratory equipment and medical-grade air supply applications. Its 100% oil-free design guarantees medical-grade air purity by eliminating the risk of aerosolized oil particles. Simultaneously, the 70L\/min flow rate and low noise operation meet the strict performance and acoustic requirements necessary for sensitive clinical environments and direct patient care areas.\u003c\/p\u003e\n\n\u003ch3\u003eDoes this pump meet the current European medical device regulations for OEM integration?\u003c\/h3\u003e\n\u003cp\u003eYes, the HC280 holds the updated CE MDR 2017\/745 certification. It is also manufactured in an ISO 13485 certified facility. This dual compliance ensures that the pump adheres to the latest European medical device safety, traceability, and quality standards, making it immediately ready for safe and legal integration by OEM buyers targeting the European healthcare sector.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154865565934,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/E4_B8_BB_E5_9B_BE-34.jpg?v=1781602448"},{"product_id":"hc210-medical-oxygenation-pump","title":"HC210 Medical Oxygenation Pump | ≤230W, ≥50L\/min, CE MDR 2017\/745","description":"_DESCRIPTION: For a home care equipment manufacturer needing CE MDR-compliant pumps for portable oxygen devices, component reliability dictates patient safety. The HC210 medical oxygenation pump is engineered specifically for these critical environments. Operating continuously on a 24-hour duty cycle, this oil-free pump delivers a dependable flow rate of ≥50L\/min at 140Kpa while consuming just ≤230W of power. With operating noise kept at a quiet ≤52dB(A), it is highly suitable for patient-proximal settings. Certified to CE MDR 2017\/745 and ISO 13485 standards, the HC210 integrates easily into systems for oxygen concentrators, hospital respiratory equipment, and medical-grade air supply lines. Available in both 220V and 110V configurations, this pump provides equipment engineers with a proven, quiet, and highly efficient pneumatic solution to ensure consistent air delivery and simplify global regulatory compliance for medical OEMs.\n\nLONG_DESCRIPTION:\n\n\u003ch2\u003eWhy Choose the HC210 Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003eFor a home care equipment manufacturer needing CE MDR-compliant pumps for portable oxygen devices, selecting the right pneumatic compressor is a matter of strict safety and clinical efficacy. Patient outcomes depend on uninterrupted, clean air delivery day and night. The HC210 medical oxygenation pump answers this exact demand by providing an oil-free, continuous 24-hour duty cycle that delivers pure air without any risk of particulate or hydrocarbon contamination. Designed specifically for integration into life-supporting and therapeutic respiratory systems, this unit ensures high-flow performance while maintaining strict acoustic limits. By keeping noise to a minimum and maximizing air output, OEMs can build quieter, more efficient medical devices for both clinical facilities and home care environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Efficiency:\u003c\/strong\u003e Operates at an economical ≤230W at rated pressure while maintaining high compression output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConsistent Flow and Pressure:\u003c\/strong\u003e Achieves a dependable air flow rate of ≥50L\/min at a rated pressure of 140Kpa through a pressure parallel flow configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Operation:\u003c\/strong\u003e Generates minimal acoustic disturbance with noise levels strictly restricted to ≤52dB(A) for patient comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Duty Lifespan:\u003c\/strong\u003e Engineered for a continuous 24-hour duty cycle to maximize operational lifespan, featuring automatic thermal protection at 145±5℃.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulatory Assurances:\u003c\/strong\u003e Fully compliant with CE MDR 2017\/745 and manufactured under ISO 13485 quality management systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Versatility:\u003c\/strong\u003e Functions safely and reliably within a broad operating ambient temperature range of -5 to 40℃.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue (HC210A-50\/1.4 \/ HC210B-50\/1.4)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHead Configuration\u003c\/td\u003e\n\u003ctd\u003ePressure parallel flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e220V\/50Hz\/1 \/ 110V\/60Hz\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise\u003c\/td\u003e\n\u003ctd\u003e≤52dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower at rated pressure\u003c\/td\u003e\n\u003ctd\u003e≤230W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir flow rate at rated pressure\u003c\/td\u003e\n\u003ctd\u003e≥50L\/min @ 140Kpa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed at rated pressure\u003c\/td\u003e\n\u003ctd\u003e1400 rpm \/ 1700 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension\u003c\/td\u003e\n\u003ctd\u003e198*96*146 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation size\u003c\/td\u003e\n\u003ctd\u003e136*70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e4.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating ambient temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to 40℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal protection\u003c\/td\u003e\n\u003ctd\u003e145±5℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor insulation class\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor value\u003c\/td\u003e\n\u003ctd\u003e8μF \/ 15μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HC210 is primarily designed as the core pneumatic driver for high-capacity \u003cstrong\u003eoxygen concentrators\u003c\/strong\u003e. In both clinical and home settings, these machines require a steady, oil-free medical-grade air supply to pass through zeolite sieve beds, which strip nitrogen and deliver purified oxygen directly to the patient. The medical oxygenation pump's flow rate of ≥50L\/min at 140Kpa ensures that 5-liter to 10-liter concentrator models receive the necessary intake volume and driving pressure to function efficiently over a continuous 24-hour duty cycle without pressure drops.\u003c\/p\u003e\n\n\u003cp\u003eBeyond concentrators, this unit serves as an essential internal component in broader \u003cstrong\u003ehospital respiratory equipment\u003c\/strong\u003e, including high-flow nasal cannula systems and continuous positive airway pressure (CPAP) or bi-level positive airway pressure (BiPAP) machines. The low acoustic profile of ≤52dB(A) is highly critical in these applications, as hospital wards and intensive care units enforce strict noise limits to promote restful patient recovery. Its specific installation footprint of 136x70 mm and manageable net weight of 4.3 kg allows biomedical engineers to easily integrate the pump into the tight chassis spaces typical of modern bedside equipment.\u003c\/p\u003e\n\n\u003cp\u003eAdditionally, the pump acts as a reliable source for \u003cstrong\u003emedical-grade air supply\u003c\/strong\u003e in centralized clinic distribution panels or mobile dental carts. Because the HC210 operates entirely without oil lubrication, it effectively eliminates the risk of hydrocarbon vapor contamination in the patient airstream. This mechanical design ensures all generated compressed air remains completely safe for direct inhalation, nebulizer therapies, or for driving delicate surgical tools that require clean, dry compressed air.\u003c\/p\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003eNavigating the global medical device market requires strict, documented adherence to international safety and quality standards. The HC210 simplifies this complex regulatory pathway for OEMs because it is manufactured under fully audited ISO 13485 quality management systems. This specific certification guarantees that every pump is produced in a facility dedicated to the strict material traceability, risk management, and consistent manufacturing processes required specifically for medical device components. Manufacturers can source this pump knowing the supply chain and production quality meet rigorous clinical expectations from day one.\u003c\/p\u003e\n\n\u003cp\u003eFurthermore, the pump aligns strictly with CE MDR 2017\/745 requirements, which is an essential factor for companies distributing medical equipment within the European Economic Area. By incorporating a pump component that already meets these high thresholds for clinical safety, biological compatibility, and electrical performance, medical device manufacturers can significantly reduce their own systemic testing times and technical documentation burdens. This compliance ensures reliable market access and reinforces end-user trust in the final therapeutic product's safety.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat are the electrical requirements and specific voltage options for this medical oxygenation pump?\u003c\/h3\u003e\n\u003cp\u003eThe HC210 series is manufactured in two distinct electrical configurations to support global manufacturing requirements. The HC210A-50\/1.4 model operates on a 220V\/50Hz power supply using an 8μF capacitor, functioning at a motor speed of 1400 rpm. The HC210B-50\/1.4 model operates on a 110V\/60Hz power supply using a larger 15μF capacitor, running at a speed of 1700 rpm. Both configurations feature a safe Class F motor insulation rating and consume ≤230W of power at their maximum rated pressure of 140Kpa.\u003c\/p\u003e\n\n\u003ch3\u003eIs the HC210 pump suitable for hospital respiratory equipment that requires non-stop continuous operation?\u003c\/h3\u003e\n\u003cp\u003eYes, this pump is engineered specifically for a continuous 24-hour duty cycle, making it highly suitable for life-support ventilators, continuous flow concentrators, and other hospital respiratory equipment. To proactively protect the motor and internal components during continuous, heavy-duty use, the unit includes an integrated thermal protection switch that automatically activates if the internal operating temperature reaches 145±5℃. It also functions safely and reliably in varying ambient facility temperatures ranging from -5 to 40℃.\u003c\/p\u003e\n\n\u003ch3\u003eHow does this specific model ensure the purity of the medical-grade air supply?\u003c\/h3\u003e\n\u003cp\u003eThe HC210 utilizes a completely oil-free pneumatic compression mechanism. This specific mechanical design prevents any lubricating oils, greases, or hydrocarbon vapors from entering the internal air path, ensuring that the final output remains clean and uncontaminated. This is a strict operational requirement for applications such as oxygen concentrators and direct patient ventilation systems, where medical-grade air purity is both legally mandated by CE MDR standards and medically required for patient safety.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154866712814,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/E4_B8_BB_E5_9B_BE-36.jpg?v=1781602471"},{"product_id":"hc100-medical-oxygenation-pump","title":"HC100 Medical Oxygenation Pump | ≥30L\/min, Oil-Free, CE MDR","description":"\u003ch2\u003eWhy Choose the HC100 Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003eWhen a respiratory therapy device OEM requires pumps with a 20,000h MTBF for critical care applications, selecting the right pneumatic component is a highly technical decision. The HC100 medical oxygenation pump is engineered specifically to meet these continuous duty requirements without compromising on acoustic performance or air purity. By maintaining a 24-hour duty cycle and utilizing an oil-free mechanism, this pump ensures that critical medical equipment functions dependably in demanding clinical environments. Procurement engineers tasked with sourcing reliable components will find that the HC100 series mitigates the risk of sudden equipment failure, thereby safeguarding patient health and reducing costly warranty claims for the manufacturer. The parallel flow pressure configuration maximizes output efficiency while maintaining a compact form factor.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir Flow Rate:\u003c\/strong\u003e Delivers ≥30L\/min (220V model) or ≥38L\/min (110V model) at a sustained pressure of 200kPa.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Noise Operation:\u003c\/strong\u003e Operates at ≤52dB(A) to ≤55dB(A), ensuring minimal auditory disturbance in patient care settings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Efficiency:\u003c\/strong\u003e Consumes ≤180W or ≤220W at rated pressure, optimizing energy use for continuous 24-hour duty cycles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e Fully compliant with CE MDR 2017\/745 and ISO 13485 for immediate medical device integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Functions reliably in ambient environments ranging from -5 to 40℃.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Protection:\u003c\/strong\u003e Integrated thermal safety mechanism activates at 145±5℃ to prevent motor damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil-Free Design:\u003c\/strong\u003e Guarantees medical-grade air purity for patient safety and entirely eliminates lubrication maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eHC100A-30\/2\u003c\/th\u003e\n      \u003cth\u003eHC100B-38\/2\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHead Configuration\u003c\/td\u003e\n      \u003ctd\u003ePressure parallel flow\u003c\/td\u003e\n      \u003ctd\u003ePressure parallel flow\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVoltage\u003c\/td\u003e\n      \u003ctd\u003e220V\/50Hz\/1\u003c\/td\u003e\n      \u003ctd\u003e110V\/60Hz\/1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNoise\u003c\/td\u003e\n      \u003ctd\u003e≤52dB(A)\u003c\/td\u003e\n      \u003ctd\u003e≤55dB(A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower at rated pressure\u003c\/td\u003e\n      \u003ctd\u003e≤180W\u003c\/td\u003e\n      \u003ctd\u003e≤220W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAir flow rate at rated pressure\u003c\/td\u003e\n      \u003ctd\u003e≥30L\/min@200kPa\u003c\/td\u003e\n      \u003ctd\u003e≥38L\/min@200kPa\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpeed at rated pressure\u003c\/td\u003e\n      \u003ctd\u003e1400 rpm\u003c\/td\u003e\n      \u003ctd\u003e1700 rpm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimension\u003c\/td\u003e\n      \u003ctd\u003e176*96*146 mm\u003c\/td\u003e\n      \u003ctd\u003e176*96*146 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation size\u003c\/td\u003e\n      \u003ctd\u003e114*70mm\u003c\/td\u003e\n      \u003ctd\u003e114*70mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e3.4 kg\u003c\/td\u003e\n      \u003ctd\u003e3.4 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating ambient temperature\u003c\/td\u003e\n      \u003ctd\u003e-5 to 40℃\u003c\/td\u003e\n      \u003ctd\u003e-5 to 40℃\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThermal protection\u003c\/td\u003e\n      \u003ctd\u003e145±5℃\u003c\/td\u003e\n      \u003ctd\u003e145±5℃\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMotor insulation class\u003c\/td\u003e\n      \u003ctd\u003eF\u003c\/td\u003e\n      \u003ctd\u003eF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCapacitor value\u003c\/td\u003e\n      \u003ctd\u003e6μF\u003c\/td\u003e\n      \u003ctd\u003e15μF\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HC100 medical oxygenation pump is specifically manufactured for integration into high-demand medical devices where consistent airflow and pressure are critical. In the production of oxygen concentrators, particularly 2-liter and higher capacity models, the pump delivers a reliable flow rate of ≥30L\/min to ≥38L\/min at 200kPa. This precise pneumatic output is necessary for pushing ambient air through zeolite sieve beds, facilitating the continuous separation of nitrogen and oxygen. The oil-free mechanism is vital in this application, as it prevents any hydrocarbon contamination from entering the patient's breathing circuit, maintaining strict medical-grade air purity.\u003c\/p\u003e\n\u003cp\u003eWithin hospital respiratory equipment, including ventilators and CPAP\/BiPAP machines, acoustic performance is a primary concern. The HC100 operates at a low noise level of ≤52dB(A) to ≤55dB(A), allowing it to be deployed in intensive care units and overnight patient wards without causing auditory distress to patients or clinical staff. The compact footprint (176*96*146 mm) and standardized installation size (114*70mm) allow OEM engineers to easily fit the compressor into tight equipment enclosures without requiring extensive internal redesigns.\u003c\/p\u003e\n\u003cp\u003eFurthermore, this medical oxygenation pump is highly suitable for centralized medical-grade air supply systems in smaller clinics or mobile field hospitals. The continuous 24-hour duty cycle and Class F motor insulation ensure that the pump can run constantly without overheating. The built-in thermal protection switch, calibrated to 145±5℃, provides an essential failsafe for these continuous-use scenarios. This operational stability makes it an ideal pneumatic core for any application demanding uninterrupted, clean air delivery.\u003c\/p\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp\u003eRegulatory compliance is a mandatory requirement for medical device manufacturers targeting global markets. The HC100 medical oxygenation pump is fully certified under CE MDR 2017\/745, ensuring it meets the strict safety and clinical performance requirements of the European Union's updated Medical Device Regulation. For OEM buyers and procurement managers, utilizing an MDR-compliant pump significantly reduces the regulatory burden during the certification process and accelerates the final product's time-to-market in European territories.\u003c\/p\u003e\n\u003cp\u003eAdditionally, HCEM Pump manufactures the HC100 series under a strict ISO 13485 quality management system. This internationally recognized standard demonstrates a comprehensive commitment to consistent design, development, and production of medical devices. Procurement engineers in North America, Europe, and Southeast Asia can rely on this certification as proof of rigorous quality control, traceability, and risk management. Every unit produced undergoes strict testing for flow rate, pressure, and noise levels before leaving the facility, providing OEMs with a highly consistent batch-to-batch component supply.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the operating voltage and frequency for the HC100 series?\u003c\/h3\u003e\n\u003cp\u003eThe HC100 series is available in two distinct configurations to suit different regional power standards. Model HC100A-30\/2 operates on a 220V\/50Hz\/1 power supply, which is standard for European and Southeast Asian markets. Model HC100B-38\/2 operates on a 110V\/60Hz\/1 power supply, making it directly compatible with North American electrical requirements.\u003c\/p\u003e\n\n\u003ch3\u003eIs the HC100 suitable for continuous use in oxygen concentrators?\u003c\/h3\u003e\n\u003cp\u003eYes, the HC100 is engineered for a continuous 24-hour duty cycle, making it highly suitable for oxygen concentrators and other hospital respiratory equipment. It features Class F motor insulation and a thermal protection mechanism set at 145±5℃ to ensure safe, continuous operation in ambient temperatures ranging from -5 to 40℃.\u003c\/p\u003e\n\n\u003ch3\u003eHow does the pump maintain medical-grade air purity?\u003c\/h3\u003e\n\u003cp\u003eThe HC100 utilizes a completely oil-free design. By eliminating the need for lubricating oils in the compression chamber, the pump prevents any particulate or hydrocarbon contamination from entering the air stream. This ensures that the output meets the stringent requirements for medical-grade air supply and ensures patient safety.\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154867826926,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/E4_B8_BB_E5_9B_BE-35.jpg?v=1781602498"},{"product_id":"hc80-medical-oxygenation-pump","title":"HC80 Medical Oxygenation Pump | 17L\/min, Oil-Free, ISO 13485","description":"\u003ch2\u003eWhy Choose the HC80 Medical Oxygenation Pump\u003c\/h2\u003e\n\u003cp\u003eWhen a hospital biomedical engineer is specifying pumps for a new oxygen concentrator production line, strict adherence to continuous performance and patient safety is non-negotiable. The reliability of the internal compressor directly impacts the efficacy of the entire respiratory device. The HC80 medical oxygenation pump provides the exact operational stability required for these critical care environments, operating on a 24-hour continuous duty cycle without the risk of oil contamination. By maintaining consistent pressure and flow parameters, this pump ensures that life-saving respiratory devices function dependably day after day, minimizing unexpected downtime and costly maintenance interventions in clinical settings.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConsistent Air Delivery:\u003c\/strong\u003e Generates a highly stable air flow rate of 17L\/min at 140Kpa pressure, ensuring adequate pneumatic power for demanding respiratory applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUltra-Quiet Operation:\u003c\/strong\u003e Engineered to minimize acoustic disturbance in clinical settings, achieving low noise levels of ≤45dB(A) for the 220V model and ≤48dB(A) for the 110V model.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Power Consumption:\u003c\/strong\u003e Operates efficiently with power at rated pressure strictly kept to ≤110W for the HC80A configuration and ≤90W for the HC80B configuration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Lightweight:\u003c\/strong\u003e Features a space-saving dimension of 145*75*125 mm and weighs only 2.05kg, making it ideal for integration into portable and space-constrained medical equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Versatility:\u003c\/strong\u003e Available in two distinct electrical configurations, offering operational speeds of 1400rpm at 220V\/50Hz\/1 and 1700rpm at 110V\/60Hz\/1 to suit global markets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerified Compliance:\u003c\/strong\u003e Fully certified to CE MDR 2017\/745 requirements and manufactured under strict ISO 13485 quality management systems for medical devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eHC80A-17\/1.4 (220V)\u003c\/th\u003e\n      \u003cth\u003eHC80B-17\/1.4 (110V)\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHead Configuration\u003c\/td\u003e\n      \u003ctd\u003ePressure parallel flow\u003c\/td\u003e\n      \u003ctd\u003ePressure parallel flow\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVoltage\u003c\/td\u003e\n      \u003ctd\u003e220V\/50Hz\/1\u003c\/td\u003e\n      \u003ctd\u003e110V\/60Hz\/1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNoise Level\u003c\/td\u003e\n      \u003ctd\u003e≤45dB(A)\u003c\/td\u003e\n      \u003ctd\u003e≤48dB(A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower at Rated Pressure\u003c\/td\u003e\n      \u003ctd\u003e≤110W\u003c\/td\u003e\n      \u003ctd\u003e≤90W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAir Flow Rate at Rated Pressure\u003c\/td\u003e\n      \u003ctd\u003e17L\/min@140Kpa\u003c\/td\u003e\n      \u003ctd\u003e17L\/min@140Kpa\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpeed at Rated Pressure\u003c\/td\u003e\n      \u003ctd\u003e1400rpm\u003c\/td\u003e\n      \u003ctd\u003e1700rpm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimension\u003c\/td\u003e\n      \u003ctd\u003e145*75*125 mm\u003c\/td\u003e\n      \u003ctd\u003e145*75*125 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Size\u003c\/td\u003e\n      \u003ctd\u003e95*65mm\u003c\/td\u003e\n      \u003ctd\u003e95*65mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e2.05kg\u003c\/td\u003e\n      \u003ctd\u003e2.05kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Industries\u003c\/h2\u003e\n\u003cp\u003eThe HC80 medical oxygenation pump is engineered specifically for OEMs manufacturing clinical and home-use respiratory therapy devices. Its primary application lies within the assembly of stationary and portable oxygen concentrators. By providing a highly consistent 17L\/min air flow rate at 140Kpa, the pump efficiently drives the pressure swing adsorption (PSA) process. This process is required to separate nitrogen from ambient air, ensuring a high-purity medical-grade air supply for patients dealing with chronic obstructive pulmonary disease (COPD), severe asthma, or acute respiratory conditions. The stability of the 140Kpa pressure ensures the zeolite sieve beds within the concentrator operate at peak efficiency.\u003c\/p\u003e\n\u003cp\u003eIn the broader context of hospital respiratory equipment, this pump serves as a highly dependable pneumatic engine for ventilators, nebulizers, and continuous positive airway pressure (CPAP) machines. The strictly oil-free design ensures that no aerosolized lubricants or volatile organic compounds contaminate the patient's breathing circuit. Furthermore, the extremely low noise profile—peaking at just 45dB(A)\u003c\/p\u003e","brand":"HCEM","offers":[{"title":"Default Title","offer_id":48154869235950,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0813\/6084\/7086\/files\/E4_B8_BB_E5_9B_BE-33.jpg?v=1781602524"}],"url":"https:\/\/hcempump.com\/collections\/oxygen-concentrator-compressor.oembed","provider":"Hcem","version":"1.0","type":"link"}